Breath-by-breath measurement of the volume displaced by diaphragm motion.

نویسندگان

  • Bhajan Singh
  • Janine A Panizza
  • Kevin E Finucane
چکیده

To develop an accurate method to measure the volume displaced by diaphragm motion (DeltaVdi) breath by breath, we compared DeltaVdi measured by a previously evaluated biplanar radiographic method (Singh B, Eastwood PR, and Finucane KE. J Appl Physiol 91: 1913-1923, 2001) at several lung volumes during vital capacity inspirations in 10 healthy and nine hyperinflated subjects with 1) DeltaVdi measured from the same chest X-rays by two previously described uniplanar methods (Petroll WM, Knight H, and Rochester DF. J Appl Physiol 69: 2175-2182, 1990; Verschakelen JA, Deschepper K, and Demendts M. J Appl Physiol 72: 1536-1540, 1992) and a proposed method that considered actual cross-sectional shape of the rib cage and spinal volume (DeltaVdi(S)); and 2) DeltaVdi(S) measured by lateral fluoroscopy in the same 10 healthy subjects. Relative to biplanar DeltaVdi, DeltaVdi(S) values from lateral chest X-rays and fluoroscopy were not different, whereas DeltaVdi values of Petroll et al. and Verschakelen et al. were increased by (means +/- SD) 1.98 +/- 1.59 and 1.16 +/- 0.82 liters, respectively (both P < 0.001). During quiet breathing, DeltaVdi(S) by lateral fluoroscopy was 66 +/- 16% of tidal volume and similar to that between functional residual capacity and one-half inspiratory capacity by the biplanar radiographic method. We conclude that accurate breath-by-breath measurements of DeltaVdi can be made by using lateral fluoroscopy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran

Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...

متن کامل

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

سنجش نشانگر زیستی IL-6در هوای بازدمی با استفاده از دستگاه جمع‌آورنده میعانات بازدمی

Background and Objective: The collection of exhaled breath condensate (EBC) is a noninvasive, safe and simple technique to obtain direct samples from lung and use for estimation of the effects of air pollution on human subjects. EBC contains several compounds including simple ions, hydrogen peroxide, proteins, cytokines, deoxyribonucleic acid (DNA), creatine, Electrolytes, trace elements and to...

متن کامل

The application of active respiratory gating technology in lung cancer radiotherapy

Objective: The technology of ABC ( Active Breathing Control) was used in breath-holding time in order to improve the accuracy of radiotherapy for lung cancer patients, and the influence of respiratory movement on diaphragm motion was analyzed and evaluated, in addition the feasibility and limitation of ABC was also assessed. Methods: 15 lung cancer patients were selected for the training of ABC...

متن کامل

Infant cardiac MRI using oscillatory ventilation: safe and effective

Background Cardiac magnetic resonance imaging (CMRI) for infants and young children typically requires sedation. General anaesthesia can eliminate motion artefact and permits controlled ventilation with breath-holding during imaging to limit respiratory artefact, but this technique typically requires frequent changes in respiratory support that may impair pulmonary function, and pauses in image...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2003