Comparison of BACTEC 13A medium and Du Pont isolator for detection of mycobacteremia.
نویسندگان
چکیده
BACTEC 13A medium (Johnston Laboratories, Towson, Md.) was compared with Isolator (Du Pont Co., Wilmington, Del.) concentrate for sensitivity, speed, and technical ease of isolation of mycobacteria from paired patient blood samples. Of 72 positive cultures, 63 were positive by both systems. Five positive cultures were detected by BACTEC 13A medium alone, and four were detected by Isolator alone. The median numbers of days to positivity were 12 for BACTEC 13A medium and 14 for Isolator concentrate. BACTEC 13A medium has an advantage over the Isolator in requiring less laboratory manipulation of the specimen but has the disadvantages of not providing isolated colonies or quantitation of organisms. Some technical problems with contamination in both systems are also discussed.
منابع مشابه
Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.
To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube requi...
متن کاملLaboratory diagnosis of mycobacterial infections in patients with acquired immunodeficiency syndrome.
Disseminated mycobacterial infections are commonly seen in acquired immunodeficiency syndrome (AIDS) patients, and laboratory culture is the best method for diagnosing these infections. In addition to conventional agar media, we used BACTEC 12A (Johnston Laboratories, Inc., Towson, Md.) broth medium for culture. More isolates of Mycobacterium avium complex and Mycobacterium tuberculosis were re...
متن کاملClinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.
The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...
متن کاملClinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.
The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and t...
متن کاملClinical comparison of isolator and BACTEC 660 resin media for blood culture.
The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 26 8 شماره
صفحات -
تاریخ انتشار 1988