Direct determination of plasma endothelin-I by chemiluminescence enzyme immunoassay.
نویسندگان
چکیده
A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fragment against the N-terminal core region of ET-1, is coupled with horseradish peroxidase (HRP). Labeled HRP activity was measured by using an enhanced chemiluminescence reaction of luminol/hydrogen peroxide. The assay was sensitive enough to detect 0.5 ng/L (0.05 pg/well) of plasma ET-1 and had no significant cross-reactivities with other related peptides, including endothelin-3 and the endothelin precursor peptide, big ET-1. Reliability of the assay was confirmed by comparison with an extraction-based procedure and a commercial kit.
منابع مشابه
Enzyme Immunoassay for the Quantitative Determination of TESTOSTERONE in Human Serum or plasma INTRODUCTION OF CHEMILUMINESCENCE IMMUNOASSAY
متن کامل
Comparison of ARCHITECT chemiluminiscent microparticle immunoassay for determination of Troponin I in serum with AXYM MEIA technology
Introduction: The aim of this study was determination of troponin I at serum using Architect (Abbott) and AxSYM System (Abbott). Troponin is regulatory subunit of the troponin complex associate with actin filament within muscle cells and it is a marker for diagnosis of myocardial damage. Methods: We used Architect STAT chemiluminescent microparticle immunoassay (CMIA) and AxSYM microparticle En...
متن کاملDirect Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کاملHighly sensitive microplate chemiluminescence enzyme immunoassay for the determination of staphylococcal enterotoxin B based on a pair of specific monoclonal antibodies and its application to various matrices
Submitted by kzhang on Mon, 09/08/2014 4:24pm Title Highly sensitive microplate chemiluminescence enzyme immunoassay for the determination of staphylococcal enterotoxin B based on a pair of specific monoclonal antibodies and its application to various matrices. Publication Type Journal Article Year of Publication 2010 Authors Liu, F, Li, Y, Song, C, Dong, B, Liu, Z, Zhang, K, Li, H, Sun, Y, Wei...
متن کاملHighly sensitive microplate chemiluminescence enzyme immunoassay for the determination of staphylococcal enterotoxin B based on a pair of specific monoclonal antibodies and its application to various matrices
published by kzhang on Mon, 09/08/2014 4:24pm Title Highly sensitive microplate chemiluminescence enzyme immunoassay for the determination of staphylococcal enterotoxin B based on a pair of specific monoclonal antibodies and its application to various matrices. Publication Type Journal Article Year of Publication 2010 Authors Liu, F, Li, Y, Song, C, Dong, B, Liu, Z, Zhang, K, Li, H, Sun, Y, Wei...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 8 Pt 1 شماره
صفحات -
تاریخ انتشار 1996