Patterns of loosening of the glenoid component.

نویسندگان

  • J Nagels
  • E R Valstar
  • M Stokdijk
  • P M Rozing
چکیده

The incidence of loosening of a cemented glenoid component in total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true anteroposterior radiographs, has been reported to be between 0% and 44%. Radiolucent lines are, however, difficult to detect and to interpret because of the mobility of the shoulder girdle and the obliquity of the glenoid which hinder standardisation of radiographs. We examined radiolucencies around cemented glenoid components in 48 patients, with a mean follow-up of 5.3 years, and found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism of loosening of this implant. In five patients we performed an additional analysis of loosening of the glenoid component using digital roentgen stereophotogrammetric analysis (RSA). After three years, three of the five implants had loosened (migration 1.2 to 5.5 mm). In only one, with gross loosening, were the radiological signs consistent with the RSA findings. When traditional radiographs are used for assessment, the rate of early loosening is underestimated. We recommend that RSA be used for this.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?

Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...

متن کامل

Survival and radiographic analysis of a glenoid component with a cementless fluted central peg.

BACKGROUND Aseptic loosening of glenoid components is a common problem associated with total shoulder arthroplasty and one cause for failure. A new cementless fluted glenoid component was developed and has shown excellent bony ingrowth in a canine model. HYPOTHESIS Clinical utilization of this cementless fluted pegged glenoid component in total shoulder arthroplasty would lower rates of radio...

متن کامل

The glenoid in shoulder arthroplasty.

Total shoulder arthroplasty is a common treatment for glenohumeral arthritis. One of the most common failure modes of total shoulder arthroplasty is glenoid loosening, causing postoperative pain, limitation of function, and potentially, the need for revision surgery. The literature has devoted considerable attention to the design of the glenoid component; efforts to better understand the biomec...

متن کامل

Arthroscopically assisted conversion of total shoulder arthroplasty to hemiarthroplasty with glenoid bone grafting.

Aseptic loosening of the glenoid component after total shoulder arthroplasty presents a considerable treatment challenge in the setting of substantial glenoid bone loss. Glenoid component explantation and bone grafting of defects have become common methods of recreating bone stock in hopes of preventing later fractures, maintaining joint kinematics, and allowing for later glenoid reimplantation...

متن کامل

Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study

Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty.Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and theuse of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objectiveis to report the radiographic outcomes of patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 84 1  شماره 

صفحات  -

تاریخ انتشار 2002