Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study
نویسندگان
چکیده
BACKGROUND The determination of the adequate depth of superior vena cava cannulae during minimally invasive cardiac surgery is important for warranting venous drainage and preventing complications during cardiopulmonary bypass. We investigated whether preoperative cardiac computed tomography might be useful for predicting the optimal depth of superior vena cava cannulae. METHODS The patients who required superior vena cava cannulation and had cardiac tomographic image among those scheduled to undergo a minimally invasive cardiac surgery were evaluated. The distance between the upper border of the clavicular sternal head and the superior vena cava-right atrium junction was measured on cardiac computed tomography. Equivalence test for the difference between the distance measured on cardiac computed tomography and the distance verified by surgeon's direct inspection in the surgical field was performed. The range -1 cm to 1 cm was predefined as an equivalence region. In addition, the distances between the upper border of the clavicular sternal head and the carina level on chest radiography were measured to compare the relative position of carina with regard to the superior vena cava-right atrium junction. RESULTS A total of 46 patients were evaluated. The distance from the upper border of the clavicular sternal head to the superior vena cava-right atrium junction measured on cardiac computed tomography and the distance verified by surgeon's inspection was equivalent, with the 95% confidence interval for the mean difference within the equivalence region (0.05-0.52, P < 0.0001). The carina level on chest radiography was found at least 2 cm above the superior vena cava-right atrium junction in all patients. CONCLUSIONS Preoperative cardiac computed tomography might be valuable for predicting the adequate depth of superior vena cava cannulae. Additionally, the carina on chest radiography might indicate a useful landmark for proper position of central venous catheter. TRIAL REGISTRATION This study has been registered at Clinical Research Information Service on 6 July 2012 (KCT0000477) .
منابع مشابه
Optimal placement of a superior vena cava cannula in minimally invasive robot-assisted cardiac surgery.
BACKGROUND Minimally invasive robot-assisted cardiac surgery is generally performed nowadays. To avoid the interference of a superior vena cava (SVC) cannula during surgery, it should be inserted before the operation. The position of this cannula is very important because it can cause poor venous drainage during operation. The proper position of the SVC cannula was investigated in the present s...
متن کاملBilateral Pulmonary Artery, Inferior Vena Cava, and Cardiac Echinococcosis: A Rare Presentation of Zoonotic Diseases
Introduction:Cystic hydatidosis is a zoonoticdisease thatis mostly observedin the Mediterranean region. This infectious disease may present throughdifferent manifestations that may delay the diagnosis and cause various complications for the patients. Most of the cases are usually diagnosed by imaging studies and the related management could be medical or surgical depending on the patient’s clin...
متن کاملCongenital Aortocaval Fistula from Right Subclavian Artery to Superior Vena Cava in an Adult with Tetralogy of Fallot
Congenital aortocaval fistula in association with complex congenital heart disease has never been described before. We represent an adult with tetralogy of fallot and an undiagnosed subclavian artery to superior vena cava fistula in previous catheterisms. He underwent surgical correction, successfully. After 8 months post operation he was doing well with improved functional capacity and no ...
متن کاملPii: S1010-7940(99)00228-6
Objective: Minimally invasive open heart surgery involves limited intrathoracic cannulation sites necessitating cardiopulmonary bypass to be initiated via peripheral access using percutaneous cannulae with the tip placed into the right atrial cavity. However, surgery involving the opening of the right heart obliges the surgeon to maintain the end of the cannulae into the vena cavae. The impeded...
متن کاملConservative management of superior vena cava injury due to hemodialysis catheter placement: A case report and literature review
We reported the case of a 78-year old woman with the inadvertent superior vena cava injury resulting from hemodialysis catheter placement. The catheter was placed through the left internal jugular vein. Hemodynamics were stable. The initial chest film illustrated an extraluminal catheter and mediastinal widening. The patient did not have hemothorax. Computed tomography venography also confirmed...