Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments
نویسندگان
چکیده
PURPOSE The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. METHODS Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. RESULTS SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). CONCLUSIONS The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.
منابع مشابه
Titanium surface alterations following the use of different mechanical instruments: a systematic review.
OBJECTIVE To systematically collect and evaluate existing evidence on the effects of different mechanical instruments on the surface characteristics of smooth and rough titanium surfaces. MATERIALS AND METHODS PubMed-MEDLINE, Cochrane-CENTRAL and EMBASE databases were searched up to December 2010 to identify appropriate studies. The eligible studies were controlled studies investigating titan...
متن کاملEffects of titanium brush on machined and sand-blasted/acid-etched titanium disc using confocal microscopy and contact profilometry.
OBJECTIVE Mechanical techniques, including scaling with metal, plastic, or ultrasonic instruments, rubber cup polishing, air-powder abrasive system and brushing with a conventional or a rotating brush, have been used for the debridement of dental implants. Recently, rotating brushes with titanium bristles (titanium brush) have been introduced for the debridement of implant surface when peri-imp...
متن کاملThe treatment of uncoated and titanium nitride-coated abutments with different instruments.
PURPOSE The aim of this in vitro study of titanium abutments was to investigate the extent of treatment traces, the roughness depth, and the quantity of titanium or, in the case of coated abutments, titanium nitride (TiN) removed from the surface after treatment with various instruments. MATERIALS AND METHODS Eleven uncoated, mechanically smoothed abutments and 11 TiN-coated abutments were us...
متن کاملApplication of novel anodized titanium for enhanced recruitment of H9C2 cardiac myoblast
Objective(s):Anodized treated titanium surfaces, have been proposed as potential surfaces with better cell attachment capacities. We have investigated the adhesion and proliferation properties of H9C2 cardiac myoblasts on anodized treated titanium surface. Materials and Methods: Surface topography and anodized tubules were examined by high-resolution scanning electron microscopy (SEM). Contro...
متن کاملEffect of UV-Photofunctionalization on Bioactivity of Titanium to Promote Human Mesenchymal Stem Cells
Background and Aim: The present study introduces photofunctionalization as a technique for tackling biological aging and increasing the bioactivity of titanium. This in-vitro study evaluated the effects of ultraviolet (UVC) light treatment of titanium surfaces with different time-related changes on the behavior and function of human mesenchymal stem cells (MSCs). Materials and Methods: MSCs we...
متن کامل