Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

نویسندگان

  • Vyas Akondi
  • Pablo Pérez-Merino
  • Eduardo Martinez-Enriquez
  • Carlos Dorronsoro
  • Nicolás Alejandre
  • Ignacio Jiménez-Alfaro
  • Susana Marcos
چکیده

PURPOSE Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. METHODS The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. RESULTS Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. CONCLUSIONS Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation.

AIM To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberra...

متن کامل

Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes

PURPOSE We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter i...

متن کامل

Comparison of higher order aberrations and contrast sensitivity after LASIK, Verisyse phakic IOL, and Array multifocal IOL.

PURPOSE To evaluate higher order aberrations and contrast sensitivity after LASIK, implantation of the Verisyse phakic intraocular lens (IOL), and refractive lens exchange with the Array multifocal IOL. METHODS In a prospective, non-randomized case series, LASIK was performed in 20 eyes with the Technolas 217z excimer laser (Bausch & Lomb, Rochester, NY), a Verisyse phakic IOL (AMO Inc, Santa...

متن کامل

Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs.

PURPOSE To compare visual acuity, total and high order wavefront aberrations (coma, spherical aberration, and other terms of high order aberration), and contrast sensitivity in 105 eyes implanted with 4 different types of intraocular lenses (IOLs) (1 multifocal apodized diffractive IOL and 3 monofocal IOLs). METHODS A prospective study comparing four types of IOLs (Alcon ReSTOR [50 eyes], Alc...

متن کامل

Wavefront-guided excimer laser vision correction after multifocal IOL implantation.

PURPOSE To investigate the use of wavefront-guided LASIK after multifocal intraocular lens (IOL) implantation to correct residual ametropia and higher order aberrations. METHODS In a prospective, nonrandomized case series, wavefront-guided LASIK was performed in 27 eyes (19 patients) after multifocal IOL implantation (Tecnis diffractive IOL, n = 20; ReSTOR diffractive IOL, n = 4; ReZoom refra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2017