Anterior segment OCT analysis of thin IntraLase femtosecond flaps.

نویسندگان

  • Jason E Stahl
  • Daniel S Durrie
  • Frank J Schwendeman
  • Allen J Boghossian
چکیده

PURPOSE Anterior segment optical coherence tomography (OCT) was used to analyze thin flaps created with the IntraLase femtosecond laser (IntraLase Corp). METHODS Twenty-five eyes of 25 patients had flaps created with the 60 kHz IntraLase femtosecond laser prior to excimer laser ablation. The desired flap thickness was 110 microm with a diameter of 8.5 mm for all eyes. At 1 month postoperatively, all eyes were evaluated with the Visante anterior segment OCT (Carl Zeiss Meditec). Four thickness measurements were obtained across the length of the flaps at the meridians of 45 degrees, 90 degrees, 135 degrees, and 180 degrees. Thus, 16 thickness measurements were analyzed for each flap. RESULTS Flaps were uniform (planar) with a mean thickness of 112 +/- 5 microm (range: 87 to 118 microm). Average standard deviation within the individual flaps was 4 microm (range: 1 to 8 microm). CONCLUSIONS The IntraLase femtosecond laser creates thin, uniform (planar) flaps with high predictability and reproducibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Thin Femtosecond Flaps with Anterior Segment Optical Coherence Tomography

Greater corneal biomechanical stability has been demonstrated following photorefractive keratectomy (PRK) compared with traditional microkeratome laser-assisted in situ keratomileusis (LASIK). Thin LASIK flaps exhibit biomechanical properties similar to PRK but with the advantage of no haze formation or pain. These findings suggest that thin flaps created with consistent thickness across the co...

متن کامل

Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography.

PURPOSE To assess and compare the morphology of laser in situ keratomileusis flaps (LASIK) created by a 60 kHz femtosecond laser and a mechanical microkeratome. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS Anterior segment optical coherence tomography (AS-OCT) (Visante) was used to assess 1 week postoperatively the morphology of...

متن کامل

In vivo structural characteristics of the femtosecond LASIK-induced opaque bubble layers with ultrahigh-resolution SD-OCT.

The authors report in vivo morphology of opaque bubble layers with ultrahigh-resolution anterior-segment optical coherence tomography (UHR-OCT) in 3 patients. Two patients were operated on with a 30-kHz IntraLase femtosecond laser (Abbott Medical Optics, Abbott Park, IL) and one patient was operated on with a 500-kHz VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). UHR-OCT images ...

متن کامل

Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome.

PURPOSE To evaluate the thickness and side-cut angle of laser in situ keratomileusis (LASIK) flaps created by 1 of 3 femtosecond lasers or a microkeratome using Fourier-domain optical coherence tomography (OCT). SETTING Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea. DESIGN Comparative case series. METHODS Flap creation for b...

متن کامل

Porcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser.

PURPOSE To compare real-time intraocular pressure (IOP) during laser in situ keratomileusis (LASIK) in porcine eyes using two types of microkeratomes. METHODS An interventional, prospective study of two microkeratomes: a Moria 2 (Moria group) and an IntraLase femtosecond laser (IntraLase Corp., Irvine, CA; IntraLase group). These devices were used to create lamellar corneal flaps in freshly e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2007