Is pulsatile blood flow no longer essential?
نویسنده
چکیده
The heart’s natural provision of pulsatile blood flow has been regarded as an essential requirement for normal organ function, especially critical organs such as the kidney, liver, and brain. However, in this issue of Circulation, Russell and colleagues1 have demonstrated that this tenet of medicine is no longer accurate. Their study examined the long-term impact of nonpulsatile blood flow as provided by a new generation of so-called continuous-flow left ventricular assist devices (LVADs), in this case the Heartmate II LVAD (Thoratec Corp, Pleasanton, Calif), on end-organ function in patients with refractory heart failure awaiting a heart transplant. These pumps draw blood from the left ventricle via a drainage cannula placed in the LV apex on a continuous basis and propel the blood by a rotary pump back into the circulation in a nonphasic flow pattern2 through a return cannula connected to the aorta. The major findings of the Heartmate II clinical trial, including both the primary cohort2 and a larger number of patients enrolled in the continuousaccess protocol,3 have previously been reported.
منابع مشابه
An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملPULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW
Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...
متن کاملEffect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملAn implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery
With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...
متن کاملStudy of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 120 23 شماره
صفحات -
تاریخ انتشار 2009