Anthropometric measurements: effect of CT depth of pretracheal soft tissue on tracheotomy tube selection.

نویسندگان

  • R N Walker
  • I J Alexander
  • J A Sartorius
  • C A Woomert
چکیده

BACKGROUND AND PURPOSE Tracheotomy is a commonly performed procedure; however, in the obese, it can be associated with a high morbidity and mortality, partially due to accidental decannulation. We hypothesize that a simple and rapid measurement of the DPST on CT will accurately predict those patients in need of an extended-length tracheotomy tube. MATERIALS AND METHODS A retrospective review of the electronic health record and available CT imaging of the neck was performed for all patients who underwent tracheotomy at a tertiary care center. Measurement of the DPST was performed and compared with the recorded tracheotomy tube used at surgery. RESULTS Five hundred twenty-two adult patients underwent an initial tracheotomy procedure, of whom 293 met the inclusion criteria for the study. A statistically significant correlation between the DPST and the need for an extended-length tracheotomy tube was seen. A discriminatory soft-tissue depth indicating the need for an extended-length tracheotomy tube was calculated. CONCLUSIONS CT measurement of the anterior soft-tissue depth is a simple tool that appears to provide a discriminatory threshold for the need for an extended-length tracheotomy tube. Further validation of this model through prospective application is needed. Although routine use of CT as a pretracheotomy evaluation is not advocated, the anatomic information is often available through prior imaging and has the potential to decrease the incidence of tracheotomy tube dislodgement in the obese and subsequent morbidity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photographic facial soft tissue analysis of healthy Iranian young adults: anthropometric and angular measurements

  Background :Soft tissue profile can be widely different in various populations. Furthermore, this profile can be also continues to change throughout life. However, there are few studies that quantitatively evaluate the soft tissue profile in Iranian population. In order to determine normal reference values of facial parts in our populations, we aimed to measure standards for facial soft tissu...

متن کامل

مقایسه اندازه‌گیری‌های به دست آمده ‌از آنالیز مک نامارا با معادل‌های پیشنهادی روی بافت نرم

Background and Aims: Cephalometric measurements cannot be performed for screening purposes, therefore orthodontists usually have to use either photographic or anthropometric measurements in such occasions. Finding a valid and reliable alternative could be of great value. The purpose of this study was to evaluate the correlation between McNamara's cephalometric unit difference and a proposed sof...

متن کامل

بررسی ضرورتهای انجام تراکئوتومی و عوارض آن در بیمارستان حضرت رسول اکرم(ص) طی سالهای 79-1374

Tracheotomy is a traditional procedure described since 2000 BC. Significant decrease in upper airway obstruction caused by infection was the most common indication of tracheotomy in the past, whereas presently its primary indication is in the long-term intensive care unit patients. Although tracheotomy is often beneficial in the selected patient, it has some related complications. Increasing kn...

متن کامل

A simple method to predict pretracheal tissue thickness to prevent accidental decannulation in the obese.

OBJECTIVE Accidental decannulation is the most common and serious complication associated with tracheostomy in obese patients. We lack a simple way to choose appropriate-size tracheostomy tubes in this patient subset. Our purpose was to 1) establish the range of trachea-to-skin soft tissue thickness (TTSSTT) in obese patients and 2) determine which easily obtained anthropometric measurements ar...

متن کامل

Effect of Tissue Composition on Dose Distribution in Electron Beam Radiotherapy

Objective: The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy.Methods: A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (ske...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2012