Alterations in preload and ejection phase indices of left ventricular performance,.
نویسندگان
چکیده
Ejection phase indices such as mean velocity of circumferential fiber shortening (V-cf), ejection fraction (EF), and mean normalized systolic ejection rate (MSER) are thought to reflect the level of left ventricular (LV) inotropic state. Although known to be influenced by changes in afterload, their response to altered preload is less certain. This question was examined in ten normal subjects studied in the supine position and after 10 min of 75 degree head-up tilt. Echo VL diameter (D) and carotid pulse recordings were used to calculate LV ejection time, V-cf, MSER, LV end-diastolic and stroke volumes (EDV and SV, by D3 formula), and ejection fraction. Systemic blood pressure (BP)was measured by cuff, and heart rate (HR) counted from the ECG. Calculated LVEDV decreased with tilt (115 plus or minus 8 to 82 plus or minus 7 ml, P smaller than 0.001), as did SV (81 plus or minus 6 to 54 plus or minus 6 ml, P smaller than 0.001), and ejection time (0.31 plus or minus 0.01 to 0.27 plus or minus 0.00 sec, P smaller than 0.001), but there was no significant change in systolic or diastolic BP or HR. V-cf, EF, and MSER were not singificantly altered by tilt (1.09 plus or minsu 0.04 to 1.12 plus or minus 0.05 circ/sec; 0.70 plus or minus 0.02 to 0.65 plus or minus 0.02; and 2.29 plus or minus 0.07 to 2.43 plus or minus 0.08 end-diastolic volumes/sec, respectively). V-cf, MSER, and EF appearrelatively unaffected by acute alterations in preload. That compensatory sympathetic responses blunted potential changes cannot be excluded, although HR was not found to have increased.
منابع مشابه
Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz
Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...
متن کاملCardiac Function in the Normal Newborn
25. Gaasch WH, Bing OHL, Cole JS, Hanley HG: Post extrasystolic compliance of the left ventricle. Circulation 56: 540, 1977 26. Taylor RR, Covell JW, Sonnenblick EH, Ross J Jr: Dependence of ventricular distensibility in the filling of the opposite ventricle. Am J Physiol 213: 711, 1967 27. Dodge HT, Sandier H, Baxley WA, Hawley RR: Usefulness and limitations of radiographic methods for determi...
متن کاملLeft Ventricular Systolic Performance, Function, and Contractility in Patients With Diastolic Heart Failure
Background—Patients with diastolic heart failure (DHF) have significant abnormalities in left ventricular (LV) diastolic function, including slow and delayed relaxation and increased chamber stiffness. Whether and to what extent these abnormalities in diastolic function occur in association with abnormalities in LV systolic performance, function, and contractility has not been investigated thor...
متن کاملReliable evaluation of left ventricular function during veno-arterial extracorporeal membrane oxygenetion
Introduction Precise assessment of left ventricular (LV) contractility during veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is crucial. However, changes in loading conditions may mask changes in LV function when assessed with load-dependent indices like LV ejection fraction (LVEF). Indeed, these indices do not reflect intrinsic LV contractility but are the result of interaction be...
متن کاملLeft ventricular beat to beat performance in atrial fibrillation: dependence on contractility, preload, and afterload.
OBJECTIVE To assess independent determinants of beat to beat variation in left ventricular performance during atrial fibrillation. DESIGN Prospective study. SETTING University hospital. PATIENTS Seven patients with chronic non-valvar atrial fibrillation. INTERVENTIONS Invasive and non-invasive haemodynamic variables were assessed using a non-imaging computerised nuclear probe, a balloon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 51 5 شماره
صفحات -
تاریخ انتشار 1975