Improved venous suppression on renal MR angiography with recessed elliptical centric ordering of K-space.

نویسندگان

  • Bernard Ho
  • Minh Chao
  • Hong Lei Zhang
  • Richard Watts
  • Martin R Prince
چکیده

PURPOSE To evaluate recessed elliptical centric ordering of k-space in renal magnetic resonance (MR) angiography. METHODS All imaging was performed on the same 1.5 T MR imaging system (GE Signa CVi) using the body coil for signal transmission and a phased array coil for reception. Gd, 30 ml, was injected manually at 2 ml/sec timed with automatic triggering (SmartPrep). In thirty patients using standard elliptical centric ordering, the scanner paused 8 seconds between detection of the leading edge of the Gd bolus and initiation of scanning beginning with the center of k-space. For the recessed-elliptical centric ordering in 20 consecutive patients, this delay was reduced to 4 seconds but the absolute center of k-space recessed in by 4 seconds such that in all patients the absolute center of k-space was acquired 8 seconds after detecting the leading edge of the bolus. On the arterial phase images signal-to-noise ratio (SNR) was measured in the aorta, each renal artery and vein and contrast-to-noise ratio (CNR) was measured relative to subcutaneous fat. The standard deviation of signal outside the patient was considered to be "noise" for calculation of SNR and CNR. Incidence of ringing artifact in the aorta and renal veins was noted. RESULTS Aorta SNR and CNR was significantly higher with the recessed technique (p = 0.02) and the ratio of renal artery signal to renal vein signal was higher with the recessed technique, 4 ± 2, compared to standard elliptical centric, 3 ± 2 (p = 0.03). Ringing artifact was also reduced with the recessed technique in both the aorta and renal veins. CONCLUSION Gadolinium-enhanced renal MR angiography is improved by recessing the absolute center of k-space.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution, contrast-enhanced magnetic resonance angiography with elliptical centric k-space ordering of supra-aortic arteries compared with selective X-ray angiography.

BACKGROUND AND PURPOSE The objective of this study was to evaluate the relative value of high-resolution, contrast-enhanced MR angiography (CE MRA) with elliptical centric k-space ordering compared with intra-arterial x-ray angiography for imaging carotid stenosis. METHODS Thirty patients with suspected stenosis of the carotid arteries were examined with CE MRA (1.5-T scanner) and x-ray angio...

متن کامل

Breathhold inhance inflow IR (BH-IFIR) with a novel 3D recessed fan beam view ordering

Introduction: The combination of arterial spin labeling technique with 3D balanced SSFP (b-SSFP) sequence for data acquisition has been recently used for non-contrast MR Angiography (MRA) in the body . Commonly, a respiratory-gated scan with bellows or navigator gating to detect diaphragmatic shift is performed with a segmented view ordering scheme. However, motion artifacts cannot be avoided i...

متن کامل

Feathering: Vertebral artery pseudostenosis with elliptical centric contrast-enhanced MR angiography.

Elliptical centric contrast-enhanced MR angiography of the cervical vasculature is a well-established technique that in many practices has replaced conventional angiography for several clinical indications, including atherosclerotic disease and dissections. Occasionally blurring or loss of signal intensity occurs in the vertebral arteries, especially in young patients with rapid circulation tim...

متن کامل

[Duration of enhancement and scan timing in three-dimensional contrast-enhanced MR angiography using the elliptical centric phase-encoding technique].

In the present study, we quantitatively investigated the relationship between the signal intensity in a vessel and the duration of contrast enhancement as well as scan timing in 3D contrast-enhanced MR angiography using an elliptical centric phase-encoding technique. A tube phantom filled with Gd-DTPA, acting as a vessel, was taken out from the field of view during data acquisition, by using th...

متن کامل

Theoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3D-MRA.

The point spread function (PSF) for contrast-enhanced three-dimensional (3D) MR angiography using the elliptical centric view order is derived. This view order has been shown previously to provide high venous suppression thereby enabling long acquisition times capable of high spatial resolution. The dependence of the PSF on TR, field of view (FOV), scan time, and trigger time are shown explicit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of X-ray science and technology

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2003