Urologic laparoscopy with a new blunt-tipped trocar: safe, rapid access without the use of fascial sutures.

نویسندگان

  • D A Ohl
  • G J Faerber
  • W W Hurd
چکیده

Fifteen patients underwent successful laparoscopic procedures where a new blunt-tipped trocar was used both to gain initial access to and to insufflate the abdominal cavity. The use of this new trocar obviates the need for the use of the Veress needle and appears to be both time-saving and possibly safer. Unlike the Hasson-type trocar, the blunt trocar technique does not require the use of fascial sutures for prevention of air leaks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of Blunt-tipped 12-mm Trocars Without Fascial Closure in Laparoscopic Live Donor Nephrectomy

OBJECTIVES Blunt-tipped trocar placement may eliminate the need for fascial closure in transperitoneal laparoscopic live donor nephrectomies (LDN). The process of 12-mm blunt-tipped trocar insertion through the abdominal wall involves fascial and muscle spreading, not incision. Coaptation of the tissue layers occurs during withdrawal of the trocar, preventing volume gaps that can be prone to he...

متن کامل

Trocar site hernias from using bladeless trocars: should fascial closure be performed?

Laparoscopic surgery is the modality of choice in the surgical treatment of colorectal malignancies. The reported incidence of trocar site hernias is 0.65-2.80% with conventional cutting-tip trocars, and this risk increases with the diameter of the trocar. Newer bladeless, blunt-tipped trocars effectively mitigate this risk, and routine fascial closure has been generally deemed unnecessary. We ...

متن کامل

Prospective Randomized Comparison of Cutting and Dilating Disposable Trocars for Access During Laparoscopic Renal Surgery

BACKGROUND AND OBJECTIVES Traditional trocar tip design for laparoscopic access incorporates cutting blades to penetrate the body wall. More recently, trocars applying tissue dilation have been used that create a smaller defect, seldom requiring fascial wound closure. Four 12-mm commercially available single-use trocar designs were evaluated for postoperative pain. METHODS The 4-trocar types ...

متن کامل

Laparoscopic Cholecystectomy; closure versus non-closure of the fascial sheath opening of the sub-umbilical port site “10 mm”.

Background: Laparoscopic Surgery (LS) may be associated with many port site complications such as hernia, bleeding, infection, subcutaneous emphysema and ugly scars. Some of these complications are serious such as obstructed port site hernia . Rate of these complications is low depending  on size and site of the port incision, type of the trocar that it is used, the condition of  the patient a...

متن کامل

Comparison of Tubal Sterilization Procedures Performed by Keyless Abdominal Rope-Lifting Surgery and Conventional CO2 Laparoscopy: A Case Controlled Clinical Study

OBJECTIVE To evaluate the safety and efficacy of Keyless Abdominal Rope-Lifting Surgery (KARS), for tubal sterilization procedures in comparison with the conventional CO2 laparoscopy. MATERIAL AND METHODS During a one-year period, 71 women underwent tubal ligation surgery. Conventional laparoscopy (N = 38) and KARS (N = 33) were used for tubal sterilization. In KARS, an abdominal access pathw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Urology

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 1994