Determination of traces of molybdenum and lead in foods by x-ray fluorescence spectrometry
نویسندگان
چکیده
An Energy Dispersive X-ray Fluorescence (EDXRF) method using X-ray emitting isotopes in combination with pre-concentration by carbonization was developed to determine the levels of Mo and Pb accumulated in foods. The samples were carbonized at temperatures range of 150-400°C for 15 min to 2 h for powdering. The powder was then quickly formed into a pellet for EDXRF analysis. This analytical method (detection limit, 0.08 mg/kg) was used to determine levels of Mo and Pb in several kinds of foods from the local kitchen markets. The analytical results indicated that higher concentration of Mo (2.51 ± 0.09 mg/kg) and Pb (0.62 ± 0.13 mg/kg) was present in pulse. The maximum lead concentration is also found in pulses with the mean value of, which is far below the maximum permissible limit (ASP, pp 235, 1980) of Pb in food (1-5 mg/kg). The possibility of determination of traces of Mo and Pb in foods by x-ray fluorescence after carbonization is evaluated by comparative studies of standard reference materials. The method enables fast and direct analysis to be carried out without lengthy sample pretreatment and thereby minimizing sample contamination on a routine basis for food monitoring. No loss (<5%) of Mo and Pb is observed and a significant matrix reduction is achieved. Our findings highlighted that this method could be used for monitoring the levels of heavy metals (like Mo and Pb) accumulation in foods within short time and people can avoid health risk due to toxic effect of food.
منابع مشابه
The effect of concentration and time of hydrothermal process on the fluorescent property of Molybdenum Diselenide nano-layers
The group of 2D materials contains almost all the elements of the periodic table. In contrast to the graphene sheet, they are abundant, this creates a variety of electronic properties including metals, semimetals, insulators and semiconductors. Band gaps of these materials are direct or indirect by ranging from ultraviolet to infrared, for this reason, have received much attention for nanoelect...
متن کاملDetermining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry
The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method, and the formation of beads. Certified reference bauxite samples were used for the cali...
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملمحاسبۀ ضخامت کمینۀ حفاظ برای اتاق ماموگرافی بهکمک کد MCNP-4C
In this study MCNP-4C code is used to simulate the least shielding requirements for a mammography room. In order to simulate the X-ray tube, a molybdenum target is irradiated by 28 keV electrons. Then, a molybdenum filter with a thickness of 30 micrometers was used to remove the low-energy parts of X-ray spectrum. Finally the dosimetry evaluations were conducted after designing the lead shield ...
متن کاملDetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...