Measuring the quality of life in mild to very severe dementia: testing the inter-rater and intra-rater reliability of the German version of the QUALIDEM.
نویسندگان
چکیده
BACKGROUND Quality of life (Qol) is an increasingly used outcome measure in dementia research. The QUALIDEM is a dementia-specific and proxy-rated Qol instrument. We aimed to determine the inter-rater and intra-rater reliability in residents with dementia in German nursing homes. METHODS The QUALIDEM consists of nine subscales that were applied to a sample of 108 people with mild to severe dementia and six consecutive subscales that were applied to a sample of 53 people with very severe dementia. The proxy raters were 49 registered nurses and nursing assistants. Inter-rater and intra-rater reliability scores were calculated on the subscale and item level. RESULTS None of the QUALIDEM subscales showed strong inter-rater reliability based on the single-measure Intra-Class Correlation Coefficient (ICC) for absolute agreement ≥ 0.70. Based on the average-measure ICC for four raters, eight subscales for people with mild to severe dementia (care relationship, positive affect, negative affect, restless tense behavior, social relations, social isolation, feeling at home and having something to do) and five subscales for very severe dementia (care relationship, negative affect, restless tense behavior, social relations and social isolation) yielded a strong inter-rater agreement (ICC: 0.72-0.86). All of the QUALIDEM subscales, regardless of dementia severity, showed strong intra-rater agreement. The ICC values ranged between 0.70 and 0.79 for people with mild to severe dementia and between 0.75 and 0.87 for people with very severe dementia. CONCLUSIONS This study demonstrated insufficient inter-rater reliability and sufficient intra-rater reliability for all subscales of both versions of the German QUALIDEM. The degree of inter-rater reliability can be improved by collaborative Qol rating by more than one nurse. The development of a measurement manual with accurate item definitions and a standardized education program for proxy raters is recommended.
منابع مشابه
Item distribution, internal consistency and inter-rater reliability of the German version of the QUALIDEM for people with mild to severe and very severe dementia
BACKGROUND The QUALIDEM is a dementia-specific Quality of life (Qol) instrument that is recommended for longitudinal studies and advanced stages of dementia. Our study aimed to develop a user guide for the German version of the QUALIDEM and to determine the item distribution, internal consistency and inter-rater reliability (IRR) of the German QUALIDEM. METHODS A user guide was developed base...
متن کاملInter-rater Reliability of the Qol-measure QUALIDEM
Background Improving access to health and nursing care aims to maintain and promote the quality of life (Qol) of care recipients. Especially in dementia research, Qol is a major outcome. QUALIDEM is an often-used dementiaspecific Qol measure. It consists of two consecutive versions, one for mild to severe and one for very severe dementia. Previous results showed an insufficient interrater relia...
متن کاملDesigning, Fabricating, and Testing the Validity and Reliability of the Digital Headband for Cervical Proprioception Assessment: A Descriptive Study
Background and Objectives: Accuracy of proprioceptive input plays an important role in cervical motor control. Several methods have been used to evaluate the accuracy of proprioceptive input as a factor of cervical injury prevention or rehabilitation. The aim of this study was to introduce a new tool for evaluating the accuracy of cervical proprioception and determine its validity and reliabili...
متن کاملReliability of Body Landmarks Analyzer for Measuring the Quadriceps Angle
Genovarum and Genovalgum are the most common postural deformities of the knee joint. A quadriceps angle is used to measure these anomalies. Methods of measuring this angle are divided into two categories: invasive and non-invasive. The purpose of the present research was to study the inter/intra rater reliability of the non-invasive Body Landmarks Analyzer method for measuring of the quadriceps...
متن کاملValidity and reliability of the Persian version of Dementia Knowledge Assessment Scale and Dementia Attitude Scale in Iranian health workers about Alzheimer’s disease
Abstract Introduction: There are various questionnaires in the world to assess the level of knowledge and attitudes of people about Alzheimer’s disease. Dementia Knowledge Assessment Scale (DKAS) and Dementia Attitude Scale (DAS) questionnaires are two well-known questionnaires in this field, respectively. The purpose of this study is translation and psychometrics evaluation of two questionnair...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International psychogeriatrics
دوره 26 5 شماره
صفحات -
تاریخ انتشار 2014