[Advanced NSCLC first pass perfusion at 64-slice CT: reproducibility of volume-based quantitative measurement].

نویسندگان

  • Fei Shan
  • Zhiyong Zhang
  • Mengsu Zeng
  • Jie Hu
  • Chunxue Bai
چکیده

BACKGROUND AND OBJECTIVE The aim of this study is to explore the reproducibility of volume-based quantitative measurement of non-small cell lung cancer (NSCLC) perfusion at 64-slice CT. METHODS Fourteen patients with proved advanced NSCLC were enrolled in this dynamic first pass volume-based CT perfusion (CTP) study (8x5 mm collimation), and they underwent the second scan within 24 h. According to the longest diameters, those patients were classified to <3 cm and >3 cm groups, and each group had 7 patients. Intradclass correlation coefficient (ICC) and Bland-Altman statistics were used to evaluate the reproducibility of CTP imaging. RESULTS In both groups of advanced NSCLC, the reproducibility with BF, BV, and PS values were good (ICC > 0.75 for all), but mean transit time (MTT) values. For advanced NSCLC (<3 cm), repeatability coefficient (RC) values with blood flow (BF), blood volume (BV), MT and permeability surface area product (PS) values were 56%, 45%, 114%, and 78%, respectively, and the 95% change intervals of RC were -39%-53%, -29%-62%, -83%-145%, and -57%-98%, respectively. For advanced NSCLC (>3 cm), those values were 46%, 30%, 59%, and 33%, respectively, and the 95% change intervals of RC were -48%-45%, -33%-26%, -54%-64%, and -18%-48%. CONCLUSION There is greater reproducibility of tumor size >3 cm than that of < or =3 cm. BF and BV could be addressed for reliable clinical application in antiangiogenesis therapeutic monitoring with advanced NSCLC patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

Interstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance.

PURPOSE To determine the interstudy reproducibility of quantitative first-pass perfusion cardiovascular magnetic resonance with comparison of 2 previously described analysis techniques. There is no published data on the interstudy reproducibility of perfusion cardiovascular magnetic resonance which can be used to determine the significance of longitudinal changes in myocardial perfusion after p...

متن کامل

Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

متن کامل

Reproducibility of tumor perfusion measurements using 15O-labeled water and PET.

UNLABELLED PET and 15O-labeled water (H215O) can be used to noninvasively monitor tumor perfusion. This allows evaluation of the direct target of antiangiogenic drugs, that is, tumor vasculature. Because these drugs often result in consolidation rather than regression of the tumor mass, a change in perfusion might be a more sensitive way to evaluate response than are indirect size measures on a...

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Zhongguo fei ai za zhi = Chinese journal of lung cancer

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2010