Cardiolock: an active cardiac stabilizer. First in vivo experiments using a new robotized device.

نویسندگان

  • Wael Bachta
  • Pierre Renaud
  • Edouard Laroche
  • Antonello Forgione
  • Jacques Gangloff
چکیده

Off-pump Coronary Artery Bypass Grafting (CABG) is still a technically difficult procedure. The mechanical stabilizers used for local suppression of the heart excursion have been demonstrated to exhibit significant residual motion, which could lead to a lack of accuracy in performing the surgical task, particularly when using a minimally invasive surgery (MIS) approach. We therefore propose a novel active stabilizer to compensate for the residual motion whose architecture is compatible with MIS. An experimental evaluation of a commercially available totally endoscopic stabilizer is first presented to demonstrate the unsatisfactory behavior of this device. Then, the interaction between the heart and a mechanical stabilizer is assessed in vivo using an animal model. Finally, the principle of active stabilization, based on the high-speed vision-based control of a piezo-actuated compliant mechanism, is presented, along with in vivo experimental results obtained using a prototype to demonstrate its efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiolock: An Active Cardiac Stabilizer

Off-pump Coronary Artery Bypass Grafting (CABG) is still today a technically difficult procedure. In fact, the mechanical stabilizers used to locally suppress the heart excursion have been demonstrated to exhibit significant residual motion. We therefore propose a novel active stabilizer which is able to compensate for this residual motion. The interaction between the heart and a mechanical sta...

متن کامل

The Cardiolock Project: Design of an Active Stabilizer for Cardiac Surgery

Coronary artery bypass grafting is a common surgical procedure that requires a high level of accuracy. To perform this procedure on a beating heart, surgeons reduce the heart motion with passive stabilizers. These devices, however, lack accuracy. Indeed, marked residual motion of the area of interest can be observed. In this paper, we address the problem with the design of an active stabilizer,...

متن کامل

Reconstitution of Sand Specimens Using a Rainer System

Air pluviation is a method of preparing laboratory models to carry out many geotechnical experiments. In this study, a new air pluviation device has been developed by the researchers. For laboratory modeling, it is important to calibrate the device using air pluviation to produce accurate specimens with desirable conditions and relative densities. A series of laboratory tests were conducted to ...

متن کامل

Robust Control of Power System Stabilizer Using World Cup Optimization Algorithm

In this paper, we propose a new optimized PID controller to stabilize the synchronous machine connected to an infinite bus. The model for the synchronous machine is 4-ordered linear Philips-Heffron synchronous machine. In this research, the parameters of the PID controller are optimally achieved by minimizing a definite fitness function to removes the unstable Eigen-value to the left side of im...

متن کامل

Robust Control of Power System Stabilizer Using World Cup Optimization Algorithm

In this paper, we propose a new optimized PID controller to stabilize the synchronous machine connected to an infinite bus. The model for the synchronous machine is 4-ordered linear Philips-Heffron synchronous machine. In this research, the parameters of the PID controller are optimally achieved by minimizing a definite fitness function to removes the unstable Eigen-value to the left side of im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer aided surgery : official journal of the International Society for Computer Aided Surgery

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2007