Efficiency curve of the ionization chamber of the SIR.

نویسنده

  • C Michotte
چکیده

The efficiency of the SIR ionization chamber versus photon energy has been obtained by an iterative method, starting from a few monoenergetic gamma-ray emitters. The relative standard uncertainty on the efficiency curve obtained is lower than 10(-2) above 65 keV. An efficiency curve for beta particles has been deduced in a similar manner, from measurements of (quasi-) pure beta emitters. The possible uses of the efficiency curve to identify inconsistent SIR data or discrepant decay scheme data are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Efficiency Studying of an Ion Chamber Simulation Using Vriance Reduction Techniques with EGSnrc

Background: Radiotherapy is an important technique of cancer treatment using ionizing radiation. The determination of total dose in reference conditions is an important contribution to uncertainty that could achieve 2%. The source of this uncertainty comes from cavity theory that relates the in-air cavity dose and the dose to water. These correction factors are determined from Monte Carlo calcu...

متن کامل

Design and fabrication of cylindrical ionization chamber for application in radiation protection

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

متن کامل

طراحی و ساخت اتاقک یونش حلقوی شکل با الکترود های محافظ گرافیتی

The development of a graphite ionization chamber in Iran is reported for first time, using graphite coatings collecting electrodes and guard rings. Its sensitive volume is about 200cm³, with a shape of a ring which is different from its older equivalents and a 7cm central hole that allows the passage of the direct radiation beam without attenuation. This kind of ionization chamber has alre...

متن کامل

طراحی و ساخت یک اتاقک یونش با صفحات موازی جهت دزیمتری پرتوهای ایکس تشخیصی

The use of gaseous ionization to calculate the absorbed dose of radiation beams is attractive because of its relative ease, suitable response, high accuracy and also cost-effectiveness. This work introduces the design and fabrication of a new parallel plate ionization chamber with two sensitive volumes. A series of standard tests was performed with x-rays, gamma radiation units, and beta source...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 56 1-2  شماره 

صفحات  -

تاریخ انتشار 2002