Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.
نویسندگان
چکیده
BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilator response to 100 micrograms salbutamol were measured in 18 asthmatic patients, who inhaled from a conventional metered dose inhaler by their own chosen metered dose inhaler technique, from a conventional metered dose inhaler by a taught metered dose inhaler technique, and from a breath actuated pressured inhaler (Autohaler). RESULTS In the 10 patients who could coordinate actuation and inhalation of the inhaler on their own deposition of aerosol in the lungs and bronchodilator response were equivalent on the three study days. By contrast, in the eight patients who could not coordinate the mean (SEM) percentage of the dose deposited in the lungs with their own inhaler technique (7.2% (3.4%] was substantial lower than those attained by the taught metered dose inhaler technique (22.8% (2.5%] and by Autohaler (20.8% (1.7%]. CONCLUSION Although of little additional benefit to asthmatic patients with good coordination, the Autohaler is potentially a valuable aid to those with poor coordination, and should be considered in preference to a conventional metered dose inhaler in any patient whose inhaler technique is not known to be satisfactory.
منابع مشابه
Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device.
Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike d...
متن کاملAerosol delivery devices in the treatment of asthma.
Nebulizers convert solutions or suspensions into aerosols with a particle size that can be inhaled into the lower respiratory tract. There are pneumatic jet nebulizers, ultrasonic nebulizers, and mesh nebulizers. Newer nebulizer designs are breath-enhanced, breath-actuated, or have aerosol-storage bags to minimize aerosol loss during exhalation. Nebulizers can be used with helium-oxygen mixture...
متن کاملClinical evaluation of a simple demand inhalation MDI aerosol delivery device.
Inhalation of medication is the preferred method for treating reversible airway obstruction; however, difficulties in the use of pressurized canisters frequently lead to suboptimal results. The Aerochamber (Monoghan Medical Corp) is a portable breath-actuated device that attaches to a metered-dose inhaler (MDI) and is designed to overcome many of the problems of aerosol delivery encountered by ...
متن کاملImprovement of pressurised aerosol deposition with Nebuhaler spacer device.
The effect on aerosol deposition from a pressurised metered dose inhaler of a 750 cm3 spacer device with a one way inhalation valve (Nebuhaler, Astra Pharmaceuticals) was assessed by means of an in vivo radiotracer technique. Nine patients with obstructive lung disease took part in the study. The pattern of deposition associated with use of a metered dose inhaler alone was compared with that ac...
متن کاملPressurised aerosol deposition in the human lung with and without an "open" spacer device.
A radiotracer technique has been used to assess aerosol delivery from a pressurised metered dose inhaler, used both with and without a 10 cm cylindrical spacer attachment (Syncroner), which has an open section in its upper surface. The radionuclide technetium-99m (99mTc) was added to sodium cromoglycate in a canister (Intal inhaler; 1 mg/puff); in vitro studies with a multistage liquid impinger...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 46 10 شماره
صفحات -
تاریخ انتشار 1991