The Vestibular Implant Input Interacts with Residual Natural Function
نویسندگان
چکیده
Objective Patients with bilateral vestibulopathy (BV) can still have residual "natural" function. This might interact with "artificial" vestibular implant input (VI-input). When fluctuating, it could lead to vertigo attacks. Main objective was to investigate how "artificial" VI-input is integrated with residual "natural" input by the central vestibular system. This, to explore (1) whether misalignment in the response of "artificial" VI-input is sufficiently counteracted by well-aligned residual "natural" input and (2) whether "artificial" VI-input is able to influence and counteract the response to residual "natural" input, to show feasibility of a "vestibular pacemaker." Materials and methods Five vestibular electrodes in four BV patients implanted with a VI were available. This involved electrodes with a predominantly horizontal response and electrodes with a predominantly vertical response. Responses to predominantly horizontal residual "natural" input and predominantly horizontal and vertical "artificial" VI-input were separately measured first. Then, inputs were combined in conditions where both would hypothetically collaborate or counteract. In each condition, subjects were subjected to 60 cycles of sinusoidal stimulation presented at 1 Hz. Gain, asymmetry, phase and angle of eye responses were calculated. Signal averaging was performed. Results Combining residual "natural" input and "artificial" VI-input resulted in an interaction in which characteristics of the resulting eye movement responses could significantly differ from those observed when responses were measured for each input separately (p < 0.0013). In the total eye response, inputs with a stronger vector magnitude seemed to have stronger weights than inputs with a lower vector magnitude, in a non-linear combination. Misalignment in the response of "artificial" VI-input was not sufficiently counteracted by well-aligned residual "natural" input. "Artificial" VI-input was able to significantly influence and counteract the response to residual "natural" input. Conclusion In the acute phase of VI-activation, residual "natural" input and "artificial" VI-input interact to generate eye movement responses in a non-linear fashion. This implies that different stimulation paradigms and more complex signal processing strategies will be required unless the brain is able to optimally combine both sources of information after adaptation during chronic use. Next to this, these findings could pave the way for using the VI as "vestibular pacemaker."
منابع مشابه
The risk of vestibular function loss after intracochlear implantation.
Sixty patients were selected for cochlear implantation and 50 of them received an intracochlear implant (Nucleus). Vestibular function was evaluated before and after surgery using a caloric test and a velocity step test. Sixteen patients had normal or residual vestibular function before surgery, 11 bilateral and 5 unilateral; in 3 of the latter patients, the ear with vestibular areflexia was el...
متن کاملEffects of EAS cochlear implantation surgery on vestibular function
CONCLUSIONS The patients who received electric acoustic stimulation (EAS) cochlear implantation had relatively good vestibular function compared with the patients who did not have residual hearing. The vestibular function was well preserved after atraumatic EAS surgery. The round window approach and soft electrode are preferred to decrease the risk of impairing vestibular function. OBJECTIVES...
متن کاملVestibular function in cochlear implant users Summary
Bal ance alterations in the postoperative of cochlear implant surgeries varies from 31 to 75%. Aim: to analyze vestibular function in the pre and postoperative periods of cochlear implanted individuals. Materials and methods: the vestibular function was assessed, through electronystagmography, in 38 patients, in the pre and postoperative of cochlear implant procedures. The main complaint of unb...
متن کاملVestibular function in cochlear implant users.
UNLABELLED Balance alterations in the postoperative of cochlear implant surgeries varies from 31 to 75%. AIM to analyze vestibular function in the pre and postoperative periods of cochlear implanted individuals. MATERIALS AND METHODS the vestibular function was assessed, through electronystagmography, in 38 patients, in the pre and postoperative of cochlear implant procedures. RESULTS The...
متن کاملResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کامل