Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.

نویسندگان

  • L F Czervionke
  • D L Daniels
  • F W Wehrli
  • L P Mark
  • L E Hendrix
  • J A Strandt
  • A L Williams
  • V M Haughton
چکیده

Artifacts related to magnetic susceptibility differences between bone and soft tissue are prevalent on gradient-recalled echo images, particularly when long echo delay times are used. These susceptibility artifacts spatially distort and artifactually enlarge bone contours. This can alter the apparent shape of the spinal canal and exaggerate the degree of spinal stenosis seen in patients with cervical spondylosis. The effects of magnetic susceptibility artifacts in gradient echo imaging were studied in a phantom model and the results were correlated with MR images obtained in patients with cervical spondylosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of magnetic susceptibility artifacts and motion in evaluating the cervical neural foramina on 3DFT gradient-echo MR imaging.

The purpose of this study was to evaluate in vitro the effects of magnetic susceptibility and motion on the estimation of neural foraminal diameter with three-dimensional Fourier transformation (3DFT) gradient-recalled MR imaging as compared with CT. A cervical spine phantom was constructed from desiccated human cervical vertebral bodies embedded in a water-based proteinaceous gel. The phantom ...

متن کامل

WEEKDAY EDUCATIONAL COURSE Everything You Wanted to Know about Magnetic Susceptibility & Why It Is Important

Gradient Recalled Echo (GRE) based MR imaging techniques have wide applications in MRI. Due to the absence of refocusing RF pulses GRE sequences are fast and since low flip angles are usually applied, GRE sequences have low specific absorption rate, hence are particularly well suited for high field MRI. While MR signal generated from GRE techniques is complex, most traditional applications rely...

متن کامل

Very Fast T2* Imaging by Using Improved Echo-Shifted Gradient-Recalled-Echo (iESGRE)

INTRODUCTION Echo-Shifted Gradient-Recalled-Echo (ESGRE) can be used to rapidly acquire MR images with strong T2* sensitivity [1, 2]. In this approach, excited spins are precessing over multiple TRs before each gradient echo is recalled. Therefore, the effective T2* weighting period in ESGRE is longer than one TR (TE>TR). This property makes it attractive in various clinical applications to sig...

متن کامل

Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries.

BACKGROUND AND PURPOSE If magnetic resonance imaging (MRI) is to compete with computed tomography for evaluation of patients with acute ischemic stroke, there is a need for further improvements in acquisition speed. METHODS Inclusion criteria for this prospective, single institutional study were symptoms of acute ischemic stroke within 24 hours onset, National Institutes of Health Stroke Scal...

متن کامل

GRASE (gradient- and spin-echo) MR of the brain.

PURPOSE To assess the clinical utility of GRASE (gradient- and spin-echo) MR imaging of the brain by comparing it with the T2-weighted turbo spin-echo technique. METHODS Fifty-three consecutive patients referred for MR imaging of the brain were studied with T2-weighted turbo spin-echo and GRASE techniques, matched for effective echo time (110 milliseconds), echo train length (eight), and spat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 1988