The use of very low noise magnetometers based on Superconducting QUantum Interference Devices (SQUIDs) enables nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) in microtesla magnetic fields. An untuned superconducting flux transformer coupled to a SQUID achieves a magnetic field noise of 10(-15) T Hz(-1/2). The frequency-independent response of this magnetometer combined with prepolarization of the nuclear spins yields an NMR signal that is independent of the Larmor frequency omega0. An MRI system operating in a field of 132 microT, corresponding to a proton frequency of 5.6 kHz, achieves an in-plane resolution of 0.7 x 0.7 mm2 in phantoms. Measurements of the longitudinal relaxation time T1 in different concentrations of agarose gel over five decades of frequency reveal much greater T1-differentiation at fields below a few millitesla. Microtesla MRI has the potential to image tumors with substantially greater T1-weighted contrast than is achievable in high fields in the absence of a contrast agent.
منابع مشابه
Microtesla MRI with dynamic nuclear polarization.
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by superconducting quantum interference device (SQUID) sensors to enable in vivo MRI at microtesla-range magnetic fields similar in strength to the Earth magnetic field. Despite significant advances in recent years, the potential of microtesla...
متن کاملMicrotesla MRI of the human brain combined with MEG.
One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single...
متن کاملSQUID-detected microtesla MRI in the presence of metal.
In magnetic resonance imaging performed at fields of 1 T and above, the presence of a metal insert can distort the image because of susceptibility differences within the sample and modification of the radiofrequency fields by screening currents. Furthermore, it is not feasible to perform nuclear magnetic resonance (NMR) spectroscopy or acquire a magnetic resonance image if the sample is enclose...
متن کاملLiquid-state NMR and scalar couplings in microtesla magnetic fields.
We obtained nuclear magnetic resonance (NMR) spectra of liquids in fields of a few microtesla, using prepolarization in fields of a few millitesla and detection with a dc superconducting quantum interference device (SQUID). Because the sensitivity of the SQUID is frequency independent, we enhanced both signal-to-noise ratio and spectral resolution by detecting the NMR signal in extremely low ma...
متن کاملMulti-sensor system for simultaneous ultra-low-field MRI and MEG
Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low fields (ULF MRI) are two methods based on the ability of SQUID (superconducting quantum interference device) sensors to detect femtotesla magnetic fields. Combination of these methods will allow simultaneous functional (MEG) and structural (ULF MRI) imaging of the human brain. In this paper, we report the first implementat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annual review of biomedical engineering
دوره 9 شماره
صفحات -
تاریخ انتشار 2007