The value of arterial spin-labeled perfusion imaging in acute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced MRI.

نویسندگان

  • Danny J J Wang
  • Jeffry R Alger
  • Joe X Qiao
  • Qing Hao
  • Samuel Hou
  • Rana Fiaz
  • Matthias Gunther
  • Whitney B Pope
  • Jeffrey L Saver
  • Noriko Salamon
  • David S Liebeskind
چکیده

BACKGROUND AND PURPOSE The purpose of this study was to evaluate the potential clinical value of arterial spin-labeled (ASL) perfusion MRI in acute ischemic stroke (AIS) through comparison with dynamic susceptibility contrast (DSC) enhanced perfusion MRI. METHODS Pseudocontinuous ASL with 3-dimensional background-suppressed gradient and spin echo readout was applied with DSC perfusion MRI on 26 patients with AIS. ASL cerebral blood flow and multiparametric DSC perfusion maps were rated for image quality and lesion severity/conspicuity. Mean ASL cerebral blood flow and DSC perfusion values were obtained in main vascular territories. Kendall coefficient of concordance was calculated to evaluate the reliability of ratings. Spearman correlation coefficients were calculated to compare ratings and quantitative perfusion values between ASL and DSC perfusion maps. RESULTS ASL cerebral blood flow and DSC perfusion maps provided largely consistent results in delineating hypoperfused brain regions in AIS. Hyperemic lesions, which also appeared frequently in the AIS cases studied, were more conspicuous on ASL cerebral blood flow than on DSC cerebral blood flow, mean transit time and time to the maximum of the tissue residual function maps. CONCLUSIONS As a rapid, noninvasive, and quantitative technique, ASL has clinical use in detecting blood flow abnormalities in patients with AIS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

Comparison of Arterial Spin Labeling and Dynamic Susceptibility Contrast Perfusion MRI in Patients with Acute Stroke

BACKGROUND The aim of this study was to evaluate whether arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) can reliably quantify perfusion deficit as compared to dynamic susceptibility contrast (DSC) perfusion MRI. METHODS Thirty-nine patients with acute ischemic stroke in the anterior circulation territory were recruited. All underwent ASL and DSC MRI perfusion scans wi...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

Combined low-dose contrast-enhanced MR angiography and perfusion for acute ischemic stroke at 3T: A more efficient stroke protocol.

BACKGROUND AND PURPOSE There is need to improve image acquisition speed for MR imaging in evaluation of patients with acute ischemic stroke. The purpose of this study was to evaluate the feasibility of a 3T MR stroke protocol that combines low-dose contrast-enhanced MRA and dynamic susceptibility contrast perfusion, without additional contrast. METHODS Thirty patients with acute stroke who un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 43 4  شماره 

صفحات  -

تاریخ انتشار 2012