Influence of respiratory variables on the on-line detection of exhaled trace gases by PTR-MS.
نویسندگان
چکیده
BACKGROUND Modern gas analysis techniques permit real time and on-line quantification of multiple volatile trace gases within a single exhalation. However, the influence of various respiratory manoeuvres affecting exhalation flow and the kinetics of metabolite release to the gas-phase remain largely unknown. METHODS We examined variation in the concentrations of selected trace gases over a range of expiratory flows (50; 100; 250 ml/s) and after 30 second periods of breathold and paced hyperventilation. On-line measurement of breath samples from healthy volunteers (n=10) was performed by proton transfer mass spectrometry. RESULTS Exhaled acetone increased with higher expiratory flow rate (805, 838, 898 ppb, p=0.02). Levels of methanol (206 vs 179 ppb, p<0.01), acetaldehyde (26 vs 22 ppb, p<0.01), ethanol (410 vs 208 ppb, p=0.01) and dimethyl sulphide (113 vs 103 ncps, p<0.01) fell significantly following 30s hyperventilation. After 30 second breathold levels of methanol (206 vs 217 ppb, p=0.02), acetone (805 vs 869 ppb, p<0.01), isoprene (348 vs 390 ppb, p=0.02) and dimethyl sulphide (113 vs 136 ncps, p=0.02) increased significantly. Variation in respiratory parameters did not significantly alters the level of acetonitrile, propanol and butyric acid within the breath of healthy subjects. CONCLUSIONS These findings demonstrate that respiratory manoeuvres significantly influence the measured concentration of a number of exhaled VOCs that are of potential importance within the clinical setting. Our results support the adoption of standardised practices for breath gas analysis by on-line and real time mass spectrometry methods.
منابع مشابه
Association of IgG4-related disease and sarcoidosis.
findings of this study are (i) PTR-MS evidence for the flow dependency of exhaled acetone; (ii) changing minute ventilation can both increase and decrease the concentrations of selected exhaled trace gases; and (iii) concentrations of certain volatiles were not significantly altered by respiratory manoeuvres in healthy volunteers. These preliminary observations may have important implications r...
متن کاملElective haemodialysis increases exhaled isoprene.
BACKGROUND Uraemic odour is a characteristic feature of patients with end-stage renal disease (ESRD). However, few investigations have been carried out into the composition of exhaled air in ESRD patients undergoing haemodialysis (HD). Increases of exhaled isoprene levels by a factor of up to 2.7 following HD have been reported. METHODS We attempted to confirm these findings in 50 patients un...
متن کاملA gas micropreconcentrator for low level acetone measurements
The goal of the project is to carry out fundamental research focused on the development semiconductor, resistive gas sensors based on metal oxides with dopants for selective trace detection of the diabetes biomarkers present in the human breath. The exhaled breath is a composition of gases: humidity, carbon dioxide, oxide, nitrogen and volatile organic compounds (VOCs). The majority breath samp...
متن کاملABSTRACT IWISH 2012 Julian King
The present paper reviews some paradigmatic applications of modeling and simulation in the context of exhaled breath analysis, which has emerged as a promising tool for collecting non-invasive and continuous information on the metabolic and physiological state of an individual. In particular, it is illustrated how real-time breath profiles of volatile organic compounds (as obtained, e.g., by PT...
متن کاملSelected ion flow tube mass spectrometry for on-line trace gas analysis in biology and medicine.
Selected ion flow tube mass spectrometry, (SIFT-MS), is a technique for simultaneous real-time quantification of several trace gases in air and exhaled breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas, using H(3)O(+), NO(+) and O(2)(+) reagent (precursor ions). Reactions between the precursor ions and the trace gas mole...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 66 10 شماره
صفحات -
تاریخ انتشار 2011