Pupillary activity measured by reflected infra-red light.
نویسندگان
چکیده
activity measured by reflected infra-red light. PHYSIOL. BEHAV. 28(5) 851-854, 1982.-A simple, reliable and inexpensive device for continuously monitoring pupillary changes is described. It is an improved version of a device first suggested by L. Stark. Infra-red light is transmitted to the iris and reflected back onto the receiver. Consequently, the device is effective only if the eye is immobile. Pupillometer ouput was related linearly to measurements made directly from motion pictures of pupil mobility. Experimental data are presented which demonstrate the stable baseline and minimal noise levels of the pupiUometer in a conditioning experiment using paralyzed cats. Pupillometer Conditioned response Pupillary behavior MEASUREMENT of pupil size has been found useful in variety of clinical and experimental situations. Static pupil-lary diameter has been measured by direct observation via an operating microscope [5] and by photography [8, 11, 19]. Pupillary motility has been measured by cinematography [10], by reflected light from the iris to a photocell outside of the eye [11, 15, 21], by direct light through the lens to a photocell within the eye [17] and by using a laser device [4]. In the latter case, the iris is scanned 50 times per second, producing a continuous representation of pupil diameter. Human pupillary size has been monitored by television [6, 7, 20] and most recently this technique has been adopted for use with animals [12]. The devices used by these researchers are somewhat complex and expensive. We sought a simple, reliable and inexpensive method to continuously monitor pupillary behavior in paralyzed cats during the acquisition or performance of a Pavlovian conditioned response. The pupillometer described here developed from the work of Lawrence Stark [14, 15, 16, 21]. It measures the area of the pupil by monitoring the amount of projected infra-red light that is reflected from the iris to a photovoltaic sensor. The DC voltage output of a circular photovoltaic sensor is proportional to the size of the iris and is, therefore, inversely proportional to the area of the pupil. Although we have not systematically studied the influence of eye color, the amount of light reflected from the iris should also be proportional to iris pigmentation. This technique may therefore be inappropriate for lightly pigmented irises. The pupillometer described in this paper is useful in preparations where one dimension of the pupil (e.g., height) is f'Lxed and the eye is motionless with respect to the recording device. Since the measurement …
منابع مشابه
Infra Red 3D Computer Mouse
The infra red 3D mouse is a three dimensional input device to a computer. It works by determining the position of an arbitrary object (like a hand) by emitting infra red signals from a number of locations and measuring the reflected intensities. To maximize stability, robustness, and use of bandwidth, the signals are designed by means of the wavelet and the RudinShapiro transforms. This also al...
متن کاملEffect of Intermittent versus Continuous Light Exposure on Pupillary Light Response, As Evaluated by Pupillometry
Objective Continuous and intermittent stimuli with green light affect the pupillary light response (PLR) differently. Since the majority of pupillometric studies use blue and red lights, we investigated the effect of continuous and intermittent stimulations on the PLR using red and blue lights. Methods Seventeen healthy subjects underwent continuous- and intermittent light stimuli, using red ...
متن کاملPupillary responses to short-wavelength light are preserved in aging
With aging, less blue light reaches the retina due to gradual yellowing of the lens. This could result in reduced activation of blue light-sensitive melanopsin-containing retinal ganglion cells, which mediate non-visual light responses (e.g., the pupillary light reflex, melatonin suppression, and circadian resetting). Herein, we tested the hypothesis that older individuals show greater impairme...
متن کاملEffect of Topical Anti-Glaucoma Medications on Late Pupillary Light Reflex, as Evaluated by Pupillometry
PURPOSE The late post-illumination pupillary response (PIPR 10-30s ) to blue light is reduced in glaucoma, suggesting that pupillometry can be used in clinical glaucoma evaluation. Since animal studies have indicated that common anti-glaucomatous agents affect the iris muscle, we investigated the short-term effect of the anti-glaucoma drugs on the pupillary light reflex and in particular on the...
متن کاملVisible and Infra-red Light Emission in Boron-Doped Wurtzite Silicon Nanowires
Silicon, the mainstay semiconductor in microelectronic circuitry, is considered unsuitable for optoelectronic applications owing to its indirect electronic band gap, which limits its efficiency as a light emitter. Here we show the light emission properties of boron-doped wurtzite silicon nanowires measured by cathodoluminescence spectroscopy at room temperature. A visible emission, peaked above...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiology & behavior
دوره 28 5 شماره
صفحات -
تاریخ انتشار 1982