Flow reproducibility of whole blood and other bodily fluids in simplified no reaction lateral flow assay devices.
نویسندگان
چکیده
The "no reaction" lateral flow assay (nrLFA) uses a simplified LFA structure with no conjugate pad and no stored reagents. In the nrLFA, the capillary-based transport time or distance is the key indicator, rather than the outcome of a biochemical reaction. Hence, the calibration and reproducibility of the nrLFA device are critical. The capillary flow properties of several membrane types (nitrocellulose, nylon, cellulose acetate, polyethersulfone, and polyvinylidene difluoride) are evaluated. Flow rate evaluations of MilliporeSigma Hi-Flow™ Plus (HF075, HF135 and HF180) nitrocellulose membranes on nrLFA are performed using bodily fluids (whole blood, blood plasma, and artificial sweat). The results demonstrate that fluids with lower viscosity travel faster, and membranes with slower flow rate exhibit higher capability to distinguish fluids with different viscosities. Reproducibility tests of nrLFA are performed on HF075, demonstrating excellent reproducibility. The coefficient of variation for blood coagulation tests performed with the nrLFA using induced coagulation was 5% for the plasma front and 2% for the RBC front. The effects of variation in blood hematocrit and sample volume are also reported. The overall results indicate that the nrLFA approach has a high potential to be commercially developed as a blood monitoring point-of-care device with simple calibration capability and excellent reproducibility.
منابع مشابه
Stereospecific Determination of Mefloquine in Whole Blood by HPLC
Mefloquine, as a racemic mixture, is used for the treatment and prophylaxis of malaria. Stereoselective pharmacodynamic and pharmacokinetic differences has been observed for mefloquine. In this study a modified stereoselective HPLC method is presented for determination of mefloquine (MFQ) enantiomers in whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with ...
متن کاملSahada Görülen Sığır Tüberkülozunun Tanısında Kullanılan Tuberculin Skin Test, IFN-γ Assay, Gerçek Zamanlı PCR ve Lateral Flow Rapid Testlerinin Karşılaştırılması
Bovine tuberculosis is an important zoonotic disease transmitted by direct contact, respiratory pathway, ingestion of unpasteurised milk and milk product, raw or undercooked meat. Tuberculosis can be difficult to diagnose based only on the clinical signs. Tuberculosis is usually diagnosed in the field with the tuberculin skin test. Sputum and other body fluids may be collected for microbiologic...
متن کاملOptimized Method for Reticulocyte Counting: Simple, Accurate, and Comparable to Flow Cytometry
Background: Reticulocytes are immature red blood cells with RNA, spending the final stages of their maturation in the peripheral blood. The number of reticulocytes in the peripheral blood is the salient evidence of the effectiveness of bone marrow to produce red blood cells. Currently, reticulocyte count is done manually or automatically in clinical laboratories. Difficulties and limitations of...
متن کاملRole of Nitric Oxide and ATP-Sensitive K+ Channels in Regulation of Basal Blood Flow and Hypercapnic Vasodilatation of Cerebral Blood Vessels in Rabbit
Background: The mechanisms underlying cerebral hypercapnic vasodilatation are not fully understood. Objective: To investigate the role of nitric oxide (NO) and ATP-sensitive potassium (KATP) channels in basal blood flow regulation and hypercapnia-induced vasodilatation in rabbit cerebral blood vessels. Methods: The change in cerebral blood flow was measured by a laser Doppler flowmeter in 18 Ne...
متن کاملLaminar mixing of high-viscous fluids by a cylindrical chaotic mixer
Laminar mixing of glycerin in a chaotic mixer is carried by means of the blob deformation method. The mixer was a cylindrical vessel with two rotational blades which move along two different circular paths with a stepwise motion protocol. The flow visualization was performed by marking of the free surface of the flow with a tracer. The effects of controlling parameters such as rotational speed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomicrofluidics
دوره 11 2 شماره
صفحات -
تاریخ انتشار 2017