Effect of reduction of the pulse rates of fluoroscopy and CINE-acquisition on x-ray dose and angiographic image quality during invasive cardiovascular procedures.
نویسندگان
چکیده
BACKGROUND Reducing digital pulse rates (PR) are known to reduce total energy during invasive cardiovascular procedures, which likely has benefits for patients and staff. Physicians may be reluctant to reduce these parameters because they fear a decline in image quality that could affect procedural outcomes. We sought to assess the effect of default rates of fluoroscopy (Fluoro) and CINE-acquisition (CINE) on total x-ray dose and image quality during invasive cardiovascular procedures. METHODS AND RESULTS We retrospectively reviewed procedures done with 2 default PRs: a standard dose cohort (PR, 15 for Fluoro and CINE), and a reduced dose cohort (PR, 10 for Fluoro and CINE). Total x-ray dose, Fluoro time, and contrast use were compared between groups. A blinded angiographic image quality assessment was then performed using an objective 10-point angiographic quality score. There were no significant differences between cohorts for fluoroscopy time or contrast use. The reduced dose cohort has a significant reduction in mean total x-ray dose (PR 15, 1763.1 mGy; PR 10, 1179.1 mGy; P<0.0001). When adjusted for potential confounders, a 38% reduction in total x-ray dose was identified (P<0.0001). There was no difference in adjusted angiographic quality score between the cohorts (PR 15, 7.90; PR 10, 8.00; P=0.67), indicating no decline in image quality with PR reduction. CONCLUSIONS Reducing default PRs during invasive cardiovascular procedures yields large and significant reductions in total x-ray energy with no decline in angiographic image quality.
منابع مشابه
Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz
Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...
متن کاملPatient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
متن کاملEvaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013
Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...
متن کاملNovel X-ray image noise reduction technology reduces patient radiation dose while maintaining image quality in coronary angiography
AIMS The consequences of high radiation dose for patient and staff demand constant improvements in X-ray dose reduction technology. This study assessed non-inferiority of image quality and quantified patient dose reduction in interventional cardiology for an anatomy-specific optimised cine acquisition chain combined with advanced real-time image noise reduction algorithms referred to as 'study ...
متن کاملOptimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2014