Assessment of blending ratio of powdered medicine mixtures by image analysis.

نویسندگان

  • Yasunori Miyazaki
  • Kaoru Miyawaki
  • Tomonobu Uchino
  • Yoshiyuki Kagawa
چکیده

In the dispensing process, powdered medicines are often blended with diluents or different kinds of powder. With blending, the mass percent of the medicine in the mixture is unknown until the active pharmaceutical ingredient is determined with techniques such as spectroscopy and chromatography. However, pharmacists need to confirm the exact blending ratio of the dispensing mixture in pharmacies. We aimed to develop a precise and concise method to measure the mass percent of powdered medicine mixtures without an expensive analytical apparatus. Digital photographs of three kinds of mixture of lactose powder, as diluents, with Adona®, Anginal®, or Asverin® powder were taken with a microscope at a 30× magnification. Thereafter, the mass percent was calculated from digital images of the mixture using calibrated color information in the YCbCr color space. A linear regression, between the mass percent and color difference signal, Cb, value was obtained from 10 to 90% of the medicines (r(2)=0.9806-9993) in all systems. The intra-day accuracy and precision were 0.67-12% (relative error) and <5% (relative standard deviation), respectively. Moreover, the mass percent measured using image analysis was consistent with the concentration of the active pharmaceutical ingredient determined spectrophotometrically. This effective image analysis method enables pharmacists to nondestructively ensure the exact mass percent of the medicine in the dispensing mixture in pharmacies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Blending powdered antineoplastic medicine in disposable ointment container].

On dispensing powdered antineoplastic medicines, it is important to prevent cross-contamination and environmental exposure. Recently, we developed a method for blending powdered medicine in a disposable ointment container using a planetary centrifugal mixer. The disposable container prevents cross-contamination. In addition, environmental exposure associated with washing the apparatus does not ...

متن کامل

Application of the Ratio Derivative Method in Quantitative Analysis of Samples Dyed with Ternary Dye Mixtures

In this study, a derivative method is applied for the determination of dye concentration in fabrics dyed with tricomponent dye mixtures. The reflectance of spectra of the samples were recorded between 400 and 700 nm. Initially, the obtained (K/S) spectra were divided by the spectrum of a standard sample dyed with two of the components in the ternary mixture and the derivative spectra were calcu...

متن کامل

Biomedical Image Denoising Based on Hybrid Optimization Algorithm and Sequential Filters

Background: Nowadays, image de-noising plays a very important role in medical analysis applications and pre-processing step. Many filters were designed for image processing, assuming a specific noise distribution, so the images which are acquired by different medical imaging modalities must be out of the noise. Objectives: This study has focused on the sequence filters which are selected ...

متن کامل

Quantitative Assessment of Conventional and Modern De-Noising on Nuclear Medicine Images

Introduction: One of the major problems in the development of nuclear medicine images is the presence of noise. The noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a Fourier transform environment. The main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times...

متن کامل

Behavior of Cu-Cr Powder Mixtures During Mechanical Alloying (TECHNICAL NOTE)

In the present work, the behavior of Cu-Cr powder mixtures during mechanical alloying has been studied. The powder mixtures with 1, 3 and 6 weight percents of Cr in Cu were treated. They were milled in a ball mill with two different speeds of 250 and 500 rpm using equal numbers of 1 and 2 centimeters balls. The weight ratio of balls to powders was 10 to 1 under argon atmosphere. Ethanol was use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical & pharmaceutical bulletin

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 2014