Keratometric Index Obtained by Fourier-Domain Optical Coherence Tomography
نویسندگان
چکیده
PURPOSE To determine the keratometric indices calculated based on parameters obtained by Fourier-domain optical coherence tomography (FD-OCT). METHODS The ratio of anterior corneal curvature to posterior corneal curvature (Ratio) and keratometric index (N) were calculated within central 3 mm zone with the RTVue FD-OCT (RTVue, Optovue, Inc.) in 186 untreated eyes, 60 post-LASIK/PRK eyes, and 39 keratoconus eyes. The total corneal powers were calculated using different keratometric indices: Kcal based on the mean calculated keratometric index, K1.3315 calculated by the keratometric index of 1.3315, and K1.3375 calculated by the keratometric index of 1.3375. In addition, the total corneal powers based on Gaussian optics formula (Kactual) were calculated. RESULTS The means for Ratio in untreated controls, post-LASIK/PRK group and keratoconus group were 1.176 ± 0.022 (95% confidence interval (CI), 1.172-1.179), 1.314 ± 0.042 (95%CI, 1.303-1.325) and 1.229 ± 0.118 (95%CI, 1.191-1.267), respectively. And the mean calculated keratometric index in untreated controls, post-LASIK/PRK group and keratoconus group were 1.3299 ± 0.00085 (95%CI, 1.3272-1.3308), 1.3242 ± 0.00171 (95%CI, 1.3238-1.3246) and 1.3277 ± 0.0046 (95%CI, 1.3263-1.3292), respectively. All the parameters were normally distributed. The differences between Kcal and Kactual, K1.3315 and Kactual, and K1.3375 and Kactual were 0.00 ± 0.11 D, 0.21 ± 0.11 D and 0.99 ± 0.12 D, respectively, in untreated controls; -0.01 ± 0.20 D, 0.85 ± 0.18 D and 1.56 ± 0.16 D, respectively, in post-LASIK/PRK group; and 0.03 ± 0.67 D, 0.56 ± 0.70 D and 1.40 ± 0.76 D, respectively, in keratoconus group. CONCLUSION The calculated keratometric index is negatively related to the ratio of anterior corneal curvature to posterior corneal curvature in untreated, post-LASIK/PRK, and keratoconus eyes, respectively. Using the calculated keratometric index may improve the prediction accuracies of total corneal powers in untreated controls, but not in post-LASIK/PRK and keratoconus eyes.
منابع مشابه
اندازهگیری همزمان ضریب شکست و ضخامت فیزیکی دستگاههای چندلایهای با استفاده از نتایج مقطعنگاری همدوسی اپتیکی در فضای فوریه
In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...
متن کاملTear meniscus analysis with Fourier-domain optical coherence tomography in keratoconus.
PURPOSE To measure the lower tear meniscus dynamics with Fourier domain-optical coherence tomography (FD-OCT) in keratoconus patients without dry eye findings to evaluate the effects of the corneal ectasia on lower tear meniscus parameters, and to determine the most affected meniscus variable from the corneal ectasia in keratoconus. METHODS Prospective, clinical study. Forty-one eyes of 25 ke...
متن کاملDemonstration of complex-conjugate-resolved harmonic Fourier-domain optical coherence tomography imaging of biological samples.
Complex-conjugate-resolved Fourier-domain optical coherence tomography, where the quadrature components of the interferogram are obtained by simultaneous acquisition of the first and second harmonics of the phase-modulated interferogram, is applied to multisurface test targets and biological samples. The method provides efficient suppression of the complex-conjugate, dc, and autocorrelation art...
متن کاملSignal-to-Signal-to-Noise-Ratio of Full-Field Fourier-Domain Optical Coherence Tomography: Experiment
We report a new approach in optical coherence tomography (OCT) termed full-field Fourier-domain OCT (3F-OCT). A three-dimensional image of a sample is obtained by digital reconstruction of a three-dimensional data cube, acquired using a Fourier holography recording system illuminated with a swept-source. This paper presents theoretical and experimental study of the signal-to-noise ratio of the ...
متن کاملOptical Coherence Tomography and Corpus Callosum Index in Cognitive Assessment of Multiple Sclerosis Patients
Background: Multiple Sclerosis (MS) is a neurodegenerative disease of central nervous system. Different approaches have been developed to study MS progression and cognitive dysfunction as the major symptom of the disease. The current study compared Optical Coherence Tomography (OCT) and Corpus Callosum Index (CCI) for the early evaluation of cognitive dysfunction in MS patients. Objectives: T...
متن کامل