Clinimetric properties of hip abduction strength measurements obtained using a handheld dynamometer in individuals with a lower extremity amputation
نویسندگان
چکیده
INTRODUCTION Suitable handheld dynamometer (HHD)-techniques to test hip abduction strength in individuals with a lower extremity amputation, irrespective of their amputation level are absent. The aim of this study was to optimise a HHD-technique and to test its reproducibility and validity. METHODS This study involved three phases, in which two techniques were evaluated. Both HHD-techniques used a lever-arm of 22 centimetre. HHD-technique 1 used a break-technique. After obtaining within-session test-retest reproducibility (phase 1) we optimised the HHD-technique by adding a fixation-belt and using a make-technique (HHD-technique 2). We tested the within-session test-retest and inter-rater reproducibility (phase 2) and the validity (phase 3) of HHD-technique 2 using an isokinetic dynamometer. New cohorts of participants were recruited for each phase. RESULTS Phase 1: we tested HHD-technique 1 in 26 participants with a lower extremity amputation. It was test-retest reproducible (ICC3.1agreement: 0.80-0.92, standard error of measurement (SEM): 3.1-4.4 Nm and smallest detectable change (SDC): 8.6-12.3 Nm). There were questions regarding the validity of the measurement, because the mean muscle torque of the residual limb and sound limb were similar, which is uncommon. Phase 2: reproducibility of HHD-technique 2 was tested in 44 participants with a lower extremity amputation. It was test-retest reproducible (ICC3.1agreement: 0.96-0.97, SEM: 3.9-4.7 Nm and SDC: 10.9-12.9 Nm) but not inter-rater reproducible despite having good reliability (ICC3.1agreement: 0.92, SEM: 6.9-7.6 Nm and SDC: 19.2-21.2 Nm). Systematic bias and bias related to the magnitude of the muscle torque was suspected. Phase 3: the concurrent validity was established in 30 healthy participants (r = 0.84). Systematic bias in measurement error was present, including a consistent overestimation of the muscle torque of 28% using the HHD. CONCLUSION HHD-technique 2 is a test-retest reproducible and valid measuring technique The technique may be further optimised by the use of an external device to stabilise the HHD.
منابع مشابه
Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subj...
متن کاملThe Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly
Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...
متن کاملEffects of examiner strength on reliability of hip-strength testing using a handheld dynamometer.
CONTEXT Hip-muscle impairments are associated with a variety of lower-extremity dysfunctions. Accurate assessment in the clinical setting can be challenging due to the strength of hip muscles relative to examiner strength. OBJECTIVE To examine the influence of examiner strength and technique on manual hip-strength testing using a handheld dynamometer. DESIGN Repeated measures. SETTING Res...
متن کاملMeasuring seated hip extensor strength using a handheld dynamometer: an examination of the reliability and validity of the protocol
[Purpose] The purpose of this study was to examine the reliability and validity of measurements of hip extensor muscle strength using a handheld dynamometer (HHD) with subjects in a sitting position. In doing so, we also aimed to establish a modified method of measurement for patients with flexion contractures in the trunk and lower extremities. [Subjects and Methods] In 20 healthy males, hip e...
متن کاملThe Relationship of Anatomical Alignment and Strength of Some Lower Extremity Muscles with Jump-landing Biomechanics: A Landing Error Scoring System Study
Background: The purpose of the present study was to investigate correlative and predictive relationship of lower extremity anatomical alignment, isometric hip abduction and external rotation strength with jump-landing biomechanics using Landing Error Scoring System (LESS). Methods: Anatomical alignment and isometric lower extremity muscle strength of 30 active...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017