Defibrillation thresholds testing of implantable cardioverter-defibrillators at implantation.

نویسنده

  • Bharat K Kantharia
چکیده

I read with interest the reports on defibrillation testing (DFT) during implantable cardioverter-defibrillator (ICD) implantation published recently in JACC (1,2). There is a significant, albeit low, risk to serious complications including death during DFT testing. If the implantation data as measured through the device are satisfactory, then should we induce ventricular fibrillation (VF) in a patient who has poor cardiac function? Should we crash a brand new car during its “test-drive” to see whether the airbags will deploy? The following cases, which are mere examples, demonstrate the professional and moral dilemma of DFT testing. Two patients with severe cardiomyopathy underwent ICD implantation with excellent parameters. In the first case, during DFT testing, first shock to provide a 10-J safety margin and a subsequent maximum output shock failed to defibrillate. External defibrillation restored sinus rhythm but with severe electromechanical dysfunction requiring emergent placement of a ventricular assist device and subsequently a heart transplantation. Was cardiomyopathy in itself responsible for the ICD failure? Did the shocks cause electromechanical dysfunction? Could the patient have survived an out-of-hospital VF episode? Did DFT testing identify deficiencies at implant? In the second case, DFT testing was not performed because of the presence of atrial fibrillation, suboptimal anticoagulation profile, and evidence of sludge in the left atrial appendage by a transesophageal echocardiogram. Elective cardioversion and DFT testing after six weeks of anticoagulation was planned. Unfortunately, in the interim period, the patient met with an unnatural mode of death. Subsequently, the patient’s wife reported that “it may not mean much . . . but the defibrillator did go off . . . many times . . . it did work . . . when my husband died. . . .” During automobile accidents the airbags drastically reduce morbidity and mortality, but there is also a spectrum of injuries associated with them (3,4). Taking the analogy of the airbags and the ICDs, both of which reduce fatalities, perhaps in the case of the first patient, the “airbag” in itself was not adequate to prevent the fatality and, if anything, perhaps caused “airbag”-associated injuries. In the case of the second patient, the “airbag” deployed appropriately but could not prevent a non-road-traffic-crash–related fatality. Needless to say, until improvements in science and technology provide conclusive evidence that the ICDs effectively and predictably provide life-saving therapy without actually testing them at the time of implantation, the dilemma of DFT testing will remain unsolved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Higher defibrillation threshold in methamphetamine cardiomyopathy patients with implantable cardioverter-defibrillator

INTRODUCTION Identification of patients with an increased risk of high defibrillation thresholds (DFTs) is important in planning implantable cardioverter-defibrillator (ICD) procedures. Clinical observations have suggested that patients with methamphetamine cardiomyopathy (MACMP) have significantly elevated defibrillation thresholds. We hypothesized that MACMP patients would have higher DFT thr...

متن کامل

Success of Device-Based Methods for Atrial Tachyarrhythmia Induction during Implantation of an Implantable Cardioverter Defibrillator with Atrial Therapy

In addition to standard ventricular therapy, cardioversion using an implantable cardioverter defibrillator (ICD) with atrial therapy is one of the many new options available for treating atrial tachyarrhythmias. New data suggest that shock efficacy for AF depends on identifying atrial defibrillation thresholds (DFT) and programming the first atrial shock to at least two times the atrial DFT [1]...

متن کامل

Elevated Defibrillation Threshold: Are Defibrillation Vectors Important?

The evaluation of the defibrillation threshold (DFT) is common after the implantation of implantable cardioverter defibrillator (ICD) devices. The goal of this standard of care is to achieve successful defibrillation of ventricular fibrillation. In patients with elevated defibrillation thresholds, alternative techniques are required to correct the situation. We describe a case in which an uncom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2005