End-tidal carbon dioxide tension reflects arterial carbon dioxide tension in the heat-stressed human with and without simulated hemorrhage.
نویسندگان
چکیده
End-tidal carbon dioxide tension (Pet(CO(2))) is reduced during an orthostatic challenge, during heat stress, and during a combination of these two conditions. The importance of these changes is dependent on Pet(CO(2)) being an accurate surrogate for arterial carbon dioxide tension (Pa(CO(2))), the latter being the physiologically relevant variable. This study tested the hypothesis that Pet(CO(2)) provides an accurate assessment of Pa(CO(2)) during the aforementioned conditions. Comparisons between these measures were made: 1) after two levels of heat stress (N = 11); 2) during combined heat stress and simulated hemorrhage [via lower-body negative pressure (LBNP), N = 8]; and 3) during an end-tidal clamping protocol to attenuate heat stress-induced reductions in Pet(CO(2)) (N = 7). Pet(CO(2)) and Pa(CO(2)) decreased during heat stress (P < 0.001); however, there was no group difference between Pa(CO(2)) and Pet(CO(2)) (P = 0.36) nor was there a significant interaction between thermal condition and measurement technique (P = 0.06). To verify that this nonsignificant trend for the interaction was not due to a type II error, Pet(CO(2)) and Pa(CO(2)) at three distinct thermal conditions were also compared using paired t-tests, revealing no difference between Pa(CO(2)) and Pet(CO(2)) while normothermic (P = 0.14) and following a 1.0 ± 0.2°C (P = 0.21) and 1.4 ± 0.2°C (P = 0.28) increase in internal temperature. During LBNP while heat stressed, measures of Pet(CO(2)) and Pa(CO(2)) were similar (P = 0.61). Likewise, during the end-tidal carbon dioxide clamping protocol, the increases in Pet(CO(2)) (7.5 ± 2.8 mmHg) and Pa(CO(2)) (6.6 ± 3.4 mmHg) were similar (P = 0.31). These data indicate that mean Pet(CO(2)) reflects mean Pa(CO(2)) during the evaluated conditions.
منابع مشابه
End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning
Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...
متن کاملInvestigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital
Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...
متن کاملComparison of end-tidal and arterial carbon dioxide measurements during anaesthesia with the laryngeal mask airway.
We have confirmed the value of measurement of end-tidal carbon dioxide concentration as an indicator of arterial carbon dioxide tension during the use of the laryngeal mask airway in healthy patients breathing spontaneously. The mean difference between arterial and end-tidal carbon dioxide tension was 0.52 kPa (range 0-1.5 kPa), which is similar to the difference which has been reported when a ...
متن کاملبررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)
Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...
متن کاملCerebral Oxygen Saturation: Graded Response to Carbon Dioxide with Isoxia and Graded Response to Oxygen with Isocapnia
BACKGROUND Monitoring cerebral saturation is increasingly seen as an aid to management of patients in the operating room and in neurocritical care. How best to manipulate cerebral saturation is not fully known. We examined cerebral saturation with graded changes in carbon dioxide tension while isoxic and with graded changes in oxygen tension while isocapnic. METHODOLOGY/PRINCIPAL FINDINGS The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Regulatory, integrative and comparative physiology
دوره 300 4 شماره
صفحات -
تاریخ انتشار 2011