Multicenter laboratory evaluation of the bioMérieux Vitek antimicrobial susceptibility testing system with 11 antimicrobial agents versus members of the family Enterobacteriaceae and Pseudomonas aeruginosa.
نویسندگان
چکیده
A four-center study in which a total of 1,082 recent clinical isolates of members of the family Enterobacteriaceae and Pseudomonas aeruginosa were examined versus 11 antimicrobial agents with the bioMérieux Vitek susceptibility test system (Hazelwood, Mo.) and the GNS-F6 card was conducted. In addition, a challenge set consisting of the same 200 organisms was examined in each of the four participating laboratories. Results obtained with the Vitek system were compared to MICs determined by a standardized broth microdilution method. For purposes of comparison, susceptibility categories (susceptible, intermediate, or resistant) were assigned on the basis of the results of both methods. The result of the broth microdilution test was considered definitive. The total category error rate with the Vitek system and the recent clinical isolates (11,902 organism-antimicrobial comparisons) was 4.5%, i.e., 1.7% very major errors, 0.9% major errors, and 1.9% minor errors. The total category error rate calculated from tests performed with the challenge set (i.e., 8,800 organism-antimicrobial comparisons) was 5.9%, i.e., 2.2% very major errors, 1.1% major errors, and 2.6% minor errors. Very major error rates higher than the totals were noted with Enterobacter cloacae versus ampicillin-sulbactam, aztreonam, ticarcillin, and ticarcillin-clavulanate and with P. aeruginosa versus mezlocillin, ticarcillin, and ticarcillin-clavulanate. Major error rates higher than the averages were observed with Proteus mirabilis versus imipenem and with Klebsiella pneumoniae versus ofloxacin. Excellent overall interlaboratory reproducibility was observed with the Vitek system. The importance of inoculum size as a primary determinant in the accuracy of susceptibility test results with the Vitek system was clearly demonstrated in this study. Specifically, when an inoculum density fourfold higher than that recommended by the manufacturer was used, high rates of false resistance results were obtained with cell wall-active antimicrobial agents versus both the Enterobacteriaceae and P. aeruginosa.
منابع مشابه
Antimicrobial susceptibility testing of carbapenems: multicenter validity testing and accuracy levels of five antimicrobial test methods for detecting resistance in Enterobacteriaceae and Pseudomonas aeruginosa isolates.
From January 1996 to May 1999, Project ICARE (Intensive Care Antimicrobial Resistance Epidemiology) received 448 nonduplicate clinical isolates of Enterobacteriaceae and Pseudomonas aeruginosa that were reported to be imipenem intermediate or resistant. However, broth microdilution (BMD) confirmatory testing at the Project ICARE central laboratory confirmed this result in only 11 of 123 (8.9%) ...
متن کاملAbility of the VITEK 2 Advanced Expert System To Identify b-Lactam Phenotypes in Isolates of Enterobacteriaceae and Pseudomonas aeruginosa
The Advanced Expert System (AES) was used in conjunction with the VITEK 2 automated antimicrobial susceptibility test system to ascertain the b-lactam phenotypes of 196 isolates of the family Enterobacteriaceae and the species Pseudomonas aeruginosa. These isolates represented a panel of strains that had been collected from laboratories worldwide and whose b-lactam phenotypes had been character...
متن کاملAbility of the VITEK 2 advanced expert system To identify beta-lactam phenotypes in isolates of Enterobacteriaceae and Pseudomonas aeruginosa.
The Advanced Expert System (AES) was used in conjunction with the VITEK 2 automated antimicrobial susceptibility test system to ascertain the beta-lactam phenotypes of 196 isolates of the family Enterobacteriaceae and the species Pseudomonas aeruginosa. These isolates represented a panel of strains that had been collected from laboratories worldwide and whose beta-lactam phenotypes had been cha...
متن کاملDiffusion disk susceptibility testing with cefotaxime.
The diffusion disk susceptibility of Staphylococcus aureus, Enterobacteriaceae, and Pseudomonas aeruginosa to cefotaxime was determined. A 30-mug disk provided data for the susceptibility of P. aeruginosa, but yielded extremely large zones of inhibition against Enterobacteriaceae. A 5-mug disk seemed to provide the most useful susceptibility data for S. aureus and Enterobacteriaceae.
متن کاملSusceptibility Testing of Pseudomonas Aeruginosa by the Vitek 2 System: a Comparison with Etest Results. Susceptibility Testing of Pseudomonas Aeruginosa by the Vitek 2 System: a Comparison with Etest Results
P. aeruginona infections need accurate antimicrobial susceptibility data, as treatment mainly relies on antibiotic effi ciency in debilitated patients. Vitek 2, a popular automated susceptibility testing method, was compared with Etest to assess its reliability on 150 Belgian P. aeruginonas isolates. Vitek 2 and Etest exhibited a high degree of concordance, but some discrepancies in clinical ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 35 8 شماره
صفحات -
تاریخ انتشار 1997