Multithreaded cardiac CT.

نویسندگان

  • Marc Kachelriess
  • Michael Knaup
  • Willi A Kalender
چکیده

Phase-correlated CT, as it is used for cardiac imaging, is the most popular and the most important but also the most demanding special CT application in the clinical routine, today. Basically, it fulfills the four-dimensional imaging task of depicting a quasiperiodically moving object at any desired motion phase with significantly reduced motion artifacts. Although image quality with phase-correlated reconstruction is far better than with standard reconstruction, there are motion artifacts remaining and improvements of temporal resolution are required. As a well-known alternative to simply decreasing rotation time, we consider a spiral cone-beam CT scanner that has G x-ray guns and detectors mounted. We call this a multisource or a multithreaded CT scanner. Aiming for improved temporal resolution the relative temporal resolution tau, which measures the fraction of a motion period that enters the image, is studied as a function of the motion rate (heart rate) and the degree of scan overlap (pitch value) for various configurations. The parameters to optimize are the number of threads G and the interthread parameters delta alpha and delta z, which are the angular and the longitudinal separation between adjacent threads, respectively. To demonstrate the improvements approximate image reconstruction of multithreaded raw data is performed by using a generalization of the extended parallel back projection cone-beam reconstruction algorithm [Med. Phys. 31(6), 1623-1641 (2004)] to the case of multithreaded CT. Reconstructions of a simulated cardiac motion phantom and of simulated semi-antropomorphic phantoms are presented for two and three threads and compared to the single-threaded case to demonstrate the potential of multithreaded cardiac CT. Patient data were acquired using a clinical double-threaded CT scanner to validate the theoretical results. The optimum angle delta alpha between the tubes is 90 degrees for a double-threaded system, and for triple-threaded scanners it is 60 degrees or 120 degrees. In all cases, delta z = 0 results as an optimum, which means that the threads should be mounted in the same transversal plane. However, the dependency of the temporal resolution on delta z is very weak and a longitudinal separation delta z not = 0 would not deteriorate image quality. The mean temporal resolution achievable with an optimized multithreaded CT scanner is a factor of G better than the mean temporal resolution obtained with a single-threaded scanner. The standard reconstructions showed decreased cone-beam artifacts with multithreaded CT compared to the single-threaded case. Our phase-correlated reconstructions demonstrate that temporal resolution is significantly improved with multithreaded CT. The clinical patient data confirm our results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rare case of squamous cell carcinoma of buccal mucosa metastasizing to interventricular septum in a young adult detected by 18F-FDG PET-CT

Metastatic tumors to the heart unlike primary cardiac tumors are not rare. Despite its frequency, cardiac metastasis is commonly detected only during autopsy as the symptoms of disseminated metastasis prevail over symptoms caused by cardiac metastasis and hence is overlooked most of the time. Tumors more commonly found metastasizing to the heart are malignancies of lung, breast, esophagus, lymp...

متن کامل

[18F]FDG PET/CT in a case of recurrent primary cardiac osteosarcoma

Primary cardiac osteosarcoma is a very rare malignancy with a high incidence of local recurrence and systemic metastasis, contributing to the poor prognosis. Radiological modalities are commonly used for the evaluation of cardiac masses. 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/computed tomography is a valuable whole-body imaging modality in ...

متن کامل

حفاظت پرتویی بیماران در سی تی آنژیوگرافی قلب

Introduction: Cardiac CT (Computed Tomography) angiography applies as a pre-exam method for evaluating the patients with medical problems in their cardiac arteries. Due to the high delivered dose in this imaging method, dose reduction techniques and imaging strategies that serve the images quality with minimum patient dose are the subjects for investigation and research studies. This study will...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

A Fast Multithreaded Out-of-Core Visualization Technique

Out–of–core rendering techniques are necessary for viewing large volume disk–resident data sets produced by many scientific applications or high resolution imaging systems. Traditional visualizers can provide real–time performance but require all of the data to be viewed to be in the RAM. We describe a multithreaded implementation of an out–of–core isosurface renderer that does not impose such ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 33 7  شماره 

صفحات  -

تاریخ انتشار 2006