Mixing implants with differing metallic compositions has been avoided for fear of galvanic corrosion and subsequent failure of the implants and of bone healing. The purpose of this study was to evaluate upper-extremity fractures treated with open reduction and internal fixation with metallic implants that differed in metallic composition placed on the same bone. The authors studied the effects of using both stainless steel and titanium implants on fracture healing, implant failure, and other complications associated with this method of fixation. Their hypothesis was that combining these metals on the same bone would not cause clinically significant nonunions or undo clinical effects from galvanic corrosion. A retrospective review was performed of 17 patients with upper-extremity fractures fixed with metal implants of differing metallic compositions. The primary endpoint was fracture union. Eight clavicles, 2 proximal humeri, 3 distal humeri, 3 olecranons, and 1 glenoid fracture with an average follow-up 10 months were reviewed. All fractures healed. One patient experienced screw backout, which did not affect healing. This study implies that mixing implants with differing metallic compositions on the same bone for the treatment of fractures does not adversely affect bone healing. No evidence existed of corrosion or an increase in complications with this method of treatment. Contrary to prior belief, small modular hand stainless steel plates can be used to assist in reduction of smaller fracture fragments in combination with anatomic titanium plates to obtain anatomic reduction of the fracture without adversely affecting healing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up

Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale ...

متن کامل

Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

متن کامل

The Prevalence of Unanticipated Hamate Hook Abnormalities in Computed Tomography Scans: A Retrospective Study

 Background:It is possible that some hamate hook fractures are not diagnosed or treated, thereby affecting the study of their natural history. Study of the prevalence of incidental hamate hook fractures, nonunions, and other abnormalities on computed tomography (CT) ordered for another reason could document a subset of undiagnosed and untreated hamate hook fractures which might change our under...

متن کامل

Economic Analysis of the Cost of Implants Used for Treatment of Distal Radius Fractures

Background: There are a number of different implant choices for surgical treatment of distal radius fractures, oftendetermined by surgeon preference or availability. Although no one volar plate demonstrates superior outcomes, thereare significant cost differences absorbed by hospitals and surgical centers. This purpose of this study is to characterizethe economic implications of implant selecti...

متن کامل

Implant Removal Matrix for the Upper Extremity Orthopedic Surgeon

Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 36 9  شماره 

صفحات  -

تاریخ انتشار 2013