The Newmarket pump: a new suction pump for external negative pressure ventilation.
نویسندگان
چکیده
A new electronically controlled pump has been developed for use with a cuirass in providing external negative pressure ventilation. It is smaller, lighter, and more versatile than currently available pumps and operates on a servo principle. A rotary valve between the pump and the cuirass varies the rate of extraction of air from the cuirass. The pressure within the cuirass is sensed by a pressure transducer, and the output of this is used to control the position of the rotary valve by means of a motor so that the pressure within the cuirass follows a predetermined half sine wave pattern. The respiratory rate varies from 10 to 30 per minute and the inspiratory to expiratory time (I/E) ratio from 3:2 to 2:3. Inspiratory pressure varies from 0 to -50 cm H2O and an expiratory pressure of 0 to +50 cm H2O can be imposed. The performance of the new pump was assessed in 21 patients with nocturnal hypoxaemia who were accustomed to external negative pressure ventilation. The mean tidal volume achieved increased with increase in cuirass suction pressure, and changing the I/E ratio from 1:1 to 3:2 produced a small increase at a cuirass negative pressure at 20 cm water. Comparison of the Newmarket pump with the Cape pump in 14 patients showed that similar tidal volumes were achieved. Overnight monitoring of cuirass pressure in one patient showed more even control of peak negative pressure with the Newmarket pump than with the Cape pump. Ten pumps are in use in patients' homes; five have been in service for more than six months and no important problems have been encountered. The new pump seems to offer advantages that make external negative pressure ventilation more acceptable.
منابع مشابه
Choosing a negative pressure ventilation pump: are there any important differences?
Five negative pressure ventilator pumps were assessed to determine whether there were any differences in performance which were likely to be of clinical importance. The pumps tested were the NEV-100 (Lifecare Inc.), the Negavent Respirator DA-1 (Dima Italia), the Thompson Maxivent (Puritan Bennett), the CCP-001 and Newmarket pumps (Si-Plan Electronics Research Ltd). A patient model was employed...
متن کاملComparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation
Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...
متن کاملMechanics of ventilation in swellsharks, Cephaloscyllium ventriosum (Scyliorhinidae).
A simple two-pump model has served to describe the mechanics of ventilation in cartilaginous and bony fishes since the pioneering work of G. M. Hughes. A hallmark of this model is that water flow over the gills is continuous. Studies of feeding kinematics in the swellshark Cephaloscyllium ventriosum, however, suggested that a flow reversal occurred during prey capture and transport. Given that ...
متن کاملPressure pulsations in reciprocating pump piping systems Part 1: modelling
A distributed parameter model of pipeline transmission line behaviour is presented, based on a Galerkin method incorporating frequency-dependent friction. This is readily interfaced to an existing model of the pumping dynamics of a plunger pump to allow time-domain simulations of pipeline pressure pulsations in both suction and delivery lines. A new model for the pump inlet manifold is also pro...
متن کاملSimulation-based Vibration Sensor Placement for Centrifugal Pump Impeller Fault Detection
In this paper, a simulation-based method is proposed for optimal placement of vibration sensors for the purpose of fault detection in a centrifugal pump. The centrifugal pump is modeled to investigate the effect of vane tip fault on fluid flow patterns numerically. Pressure pulsations are investigated at different locations at the inner surface of the pump before and after the presence of the f...