Influence of Light Curing Source on Microhardness of Composite Resins of Different Shades
نویسندگان
چکیده
INTRODUCTION The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. PURPOSE This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). METHODS 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. RESULTS The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. CONCLUSION Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.
منابع مشابه
Influence of the Distance of the Curing Light Source and Composite Shade on Hardness of Two Composites
This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The spe...
متن کاملInfluence of different shades and LED irradiance on the degree of conversion of composite resins.
The aim of this study was to evaluate the degree of conversion (DC) of two composite resins with different shades that were light cured by light-emitting diodes (LEDs) of different irradiances. Specimens (5 mm ' 2 mm) were prepared with a nanofilled (Filtek Supreme - A2E, A2D, and WE) or microhybrid resin (Opallis - A2E, A2D, and EBleach Low) and were randomly divided into 12 groups (n = 5 each...
متن کاملEffect of composite shade, curing time and mode on temperature rise of silorane and methacrylate- based composite resins
Introduction: The present study was performed to evaluate the effects of light-curing modes and shades of methacrylate and silorane-based composite resins on temperature rise during polymerization of composite resins. Materials &Methods: In this in vitro study, ninety composite samples with two types of composite resin - methacrylate-based and a low-shrinkage silorane-based were prepared, in...
متن کاملEffect of Curing Time on Polymerization Rate of Bulk-Fill Composite Resins
Objectives: The aim of this study was to compare polymerization depth of two bulk-fill and one conventional composite cured for different times. Methods: This in vitro experimental study was conducted on 54 composite samples (2×4×10mm) fabricated of Tetric N-Ceram bulk-fill, x-tra fil bulk-fill, and Grandio conventional composite cured for 20, 30, and 40 seconds. The microhardnes...
متن کاملMicrohardness Evaluation of a Direct/Indirect Hybrid Composite Resin at Complementary Activation in Light or Heat
This investigation aims at determining the microhardness value of the hybrid direct/indirect composite resins submitted to conventional light curing and post-cured using two different methods, a light source from a laboratory light curing unit and a conventional oven heating, and the obtained results were compare to an indirect composite resin. A hybrid direct/indirect composite resin (Filtek P...
متن کامل