Relation of optic disc topography and age to thickness of retinal nerve fibre layer as measured using scanning laser polarimetry, in normal subjects.
نویسندگان
چکیده
AIMS To evaluate the relation of the optic nerve head topographic measurements and age with the thickness of the retinal nerve fibre layer (RNFL) in normal Caucasoid subjects by means of scanning laser polarimetry and tomography. METHODS Topographic optic disc measurements and RNFL thickness values of 38 normal Caucasoid subjects of both sexes aged 20 to 78 were measured using a confocal scanning laser ophthalmoscope and a confocal scanning laser polarimeter. One eye was randomly selected for statistical analysis. The effects of optic disc size, age, and optic disc head topographic measurements of total and regional RNFL thickness were evaluated. RESULTS Age showed a significant correlation with the integral of the total RNFL thickness (R=-0.341, p<0.05). The optic disc size showed a significant correlation with the integral of the total, superior, and inferior quadrant RNFL thickness (R=0.425, p<0.01), (R=0.361, p<0.05), (R=0.468, p<0.05). Neuroretinal rim area (NRA) had a correlation with the superior and inferior quadrant RNFL thickness values (R=0.339, p<0.05) (R=0.393, p<0.05). There was no significant correlation between the other optic disc topographic measurements and RNFL thickness values (p>0.05). CONCLUSION The thickness of total as well as superior and inferior quadrant peripapillary RNFL as measured by scanning laser polarimetry increased significantly with an increase in optic disc size. The cross sectional area occupied by superior and inferior polar RNFL increased significantly with an increase in NRA. The total cross sectional area occupied by RNFL decreased significantly with an increase in age. The effects of optic disc size, age, and NRA should be considered when the peripapillary RNFL thickness is evaluated.
منابع مشابه
Relation between size of optic disc and thickness of retinal nerve fibre layer in normal subjects.
AIMS To evaluate the relation between the optic disc size and the thickness of the peripapillary retinal nerve fibre layer (RNFL) in normal Japanese subjects by means of scanning laser polarimetry. METHODS Scanning laser polarimetry was performed in 60 normal subjects. One eye of each subject was randomly selected for study. Using a scanning laser polarimeter, the integral of RNFL thickness w...
متن کاملVariation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry.
AIMS Scanning laser polarimetry is a new technique allowing quantitative analysis of the retinal nerve fibre layer in vivo. This technique was employed to investigate the variation of the retinal nerve fibre layer thickness in a group of normal subjects of different ages and ethnic groups. METHODS 150 normal volunteers of different ages and ethnic groups were recruited for this study. Three c...
متن کاملEVects of artefacts on scanning laser polarimetry of retinal nerve fibre layer thickness measurement
Aims—To investigate the eVects of artefacts on scanning laser polarimetry of the retinal nerve fibre layer. Methods—Six eyes of six normal volunteers and an artificial nerve fibre layer were examined using the nerve fibre analyser II. The retinal nerve fibre layer thickness (RNFLT) was measured in each of four 90 degree quadrants, superior (S), temporal (T), inferior (I), and nasal (N), at 1.5 ...
متن کاملComparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma
BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...
متن کاملRetinal nerve fibre layer polarimetry: histological and clinical comparison.
AIMS To compare histological thickness of the retinal nerve fibre layer in the primate with retardation measurements obtained in vivo using the Mark II Nerve Fiber Analyzer (NFA, Laser Diagnostic Technologies, San Diego, USA). METHODS Scanning laser polarimetry was performed on both eyes of a healthy anaesthetised adult primate (Macaca mulatta). The retinal nerve fibre layer thickness was mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 84 5 شماره
صفحات -
تاریخ انتشار 2000