Improved separation of tissue oxygenation extraction fraction and deoxygenated blood volume by using the qBOLD tech- nique

نویسندگان

  • J. Sedlacik
  • J. R. Reichenbach
  • C. M. Hillenbrand
چکیده

Introduction: He and Yablonskiy introduced a quantitative BOLD method (qBOLD) for estimation of the oxygenation extraction fraction (OEF) and the deoxygenated blood volume (DBV) in brain tissue [1]. In qBOLD, the signal course of a spin echo scan is compared to tissue model curves. The model incorporates assumptions about the blood capillaries, parenchyma, interstitial/cerebrospinal fluid, and static macroscopic field inhomogeneities; OEF and DBV are a subset of all these model variables, they are estimated by fitting the modeled to the measured signal decay, and the best match between MR signal and respective model functions is assumed to exhibit the true OEF and DBV. It has been observed that the input variables OEF and DBV barely affect the magnitude or real part of the modeled complex MR signal; also several combinations of OEF and DBV may match the original signal and therefore introduce ambiguity (Fig. 1, left) [2]. The imaginary part of the signal is, however, decoupled from the signal of the model tissue matrix and could potentially better determine OEF and DBV parameters. Hence, in this work we focus on the imaginary part of the signal as compared to the real part and assess whether the root mean square error (RMSE), a quality measure of the fit to identify the best model parameters, delivers a clearer minimum with no ambiguity for OEF and DBV than the original qBOLD approach. Methods: Signal time curves encompassing the time point of the spin echo were calculated for the tissue model according to the primary publication of qBOLD [1]. The following parameters were chosen: OEF=45%, DBV=2.5%, R2, tissue=0.1s , hematocrit=0.45, and Δχdo =0.18 ppm (cgs) which represents the difference in magnetic susceptibility between fully oxygenated and deoxygenated red blood cells [3]. All other model parameters, such as the fraction of the interstitial/cerebrospinal fluid and macroscopic static field inhomogeneities, as well as noise were set to zero in order to simplify the model. The signal time curves were calculated in steps of milliseconds starting 30ms before the actual spin echo and ending 70ms thereafter. RMSEs were determined between a reference curve which was calculated for an OEF/DBV pair of 45%/2.5% and other curves simulated with varying OEF and DBV parameters where OEF was varied between 0 and 100% and DBV between 0 and 5%. Results: The real and imaginary part of the signal is shown in Fig.1 for a subset of different OEF and DBV parameters. The signal’s real part shows similar curves with slightly higher or lower slopes whereas the imaginary part produces curves which differ significantly as a function of OEF and DBV when compared to the curves of the real part of the signal. Calculated RMSEs of the curves of all OEF and DBV combinations are shown with respect to the reference curve in Fig. 2. The RMSEs of the real part of the signal show a wide range of OEF/DBV pairs that produce signal curves which well fit to the reference curve and produce low RMSEs. In contrast, the RMSEs of the imaginary part show a clear minimum which coincides with the correct parameter set of the reference curve. Discussion/Conclusion: Our results suggests that a fitting routine which incorporates only the signal’s real part could easily stop the optimization process if it hits an OEF/DBV pair which produces a low RMSE value but represents not the correct OEF/DBV combination. However, the imaginary part of the tissue model is more sensitive to independent changes of the OEF or DBV parameters which in turn better delineates the correct OEF/DBV pair in the RMSE plot as compared to the real part. Thus, we propose that a fitting routine which optimizes both the RMSEs of the signal curves’ real and imaginary part estimates the model parameters OEF and DBV more reliably than one that fits the magnitude or real part only. However, the simplification of the model in our study limits its significance, since static field inhomogeneities and the frequency shift between the parenchyma and the interstitial/cerebrospinal fluid also introduce signal changes into the imaginary part and have to be corrected for or considered in the calculation. Further studies are needed to investigate the robustness of this approach in an in vivo setting. Literature: [1] He X et al. MRM 57:115-26, 2007. [2] Sedlacik J et al. Proc. of ISMRM 3104, 2008. [3] Weisskoff RM et al. MRM 24:375-383, 1992. Figure 1: Signal curves obtained for different OEF and DBV parameters. Both signal curves are plotted relative to the total signal at the spin echo time point (t=0). Here the real part equals one and the imaginary part is zero. Left: Real part of the complex signal. A logarithmic scale was chosen for better visualization. Right: Imaginary part of the signal in a linear scale. Note the lower amplitude of the imaginary part compared to the real part.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of oxygen extraction fraction measurement by qBOLD technique.

Measurement of brain tissue oxygen extraction fraction (OEF) in both baseline and functionally activated states can provide important information on brain functioning in health and disease. The recently proposed quantitative BOLD (qBOLD) technique is MRI-based and provides a regional in vivo OEF measurement (He and Yablonskiy, MRM 2007, 57:115-126). It is based on a previously developed analyti...

متن کامل

A streamlined acquisition for mapping baseline brain oxygenation using quantitative BOLD

Quantitative BOLD (qBOLD) is a non-invasive MR technique capable of producing quantitative measurements of the haemodynamic and metabolic properties of the brain. Here we propose a refinement of the qBOLD methodology, dubbed streamlined-qBOLD, in order to provide a clinically feasible method for mapping baseline brain oxygenation. In streamlined-qBOLD confounding signal contributions are minimi...

متن کامل

Error analysis of qBOLD technique for measurement brain hemodynamics

Introduction: qBOLD (quantitative Blood Oxygenation Level Depend) technique introduced in [1] and validated in [2] provides an MRI-based method to measure tissue hemodynamic parameters such as oxygen extraction fraction (OEF) and deoxyhemoglobincontaining (veins and pre-vinous part of capillaries) cerebral blood volume fraction (dCBV). It is based on a theory of MR signal dephasing in the prese...

متن کامل

Quantitative OEF Determination by Separate T2 and T2* Mapping

measurement of oxygenation is of great interest, because tumor oxygenation is an indicator of aggressiveness and affinity to metastazation [1]. Moreover, the chance of success of a radiation therapy or chemo therapy depends on the oxygen partial pressure of the tumorous tissue [2]. That is the reason why hypoxia is a large obstacle to tumor therapy [3]. In this study, a model of static dephasin...

متن کامل

Dispersion Parameters and Effect of Impeller Speed, Holdup and Volume Fraction of Dispersed Phase on Separation Efficiency, Mass Transfer Coefficient of Dispersed Phase and Distribution Coefficient on Mixer-Settler Set

An experimental study has been conducted on the hydrodynamics of a stage mixer-settler to obtain an appropriate design. In this paper several tests was performed to investigate full factorial design of experiments. Since each test was repeated seven times, the repeatability of the test was confirmed (P=1 bar and T=25 °C). Sauter diameter was determined by photographing both the mix...