Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device HeartMate II.
نویسندگان
چکیده
BACKGROUND Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding. METHODS AND RESULTS The Utah Transplantation Affiliated Hospitals (U.T.A.H.) heart failure and transplant program databases were queried for patients with end-stage heart failure who required support with the continuous-flow LVAD HeartMate II (Thoratec Corp, Pleasanton, CA) between 2004 and 2012. Pulsatility was evaluated by means of the LVAD parameter pulsatility index (PI) and by the echocardiographic assessment of aortic valve opening during the first 3 months of LVAD support. PI was analyzed as a continuous variable and also stratified according to tertiles of all the PI measurements during the study period (low PI: <4.6, intermediate PI: 4.6-5.2, and high PI: >5.2). Major nonsurgical bleeding associated with a decrease in hemoglobin ≥2 g/dL (in the absence of hemolysis) was the primary end point. A total of 134 patients (median age of 60 [interquartile range: 49-68] years, 78% men) were included. Major bleeding occurred in 33 (25%) patients (70% gastrointestinal, 21% epistaxis, 3% genitourinary, and 6% intracranial). In multivariable analysis, PI examined either as a categorical variable, low versus high PI (hazard ratio, 4.06; 95% confidence interval, 1.35-12.21; P=0.04), or as a continuous variable (hazard ratio, 0.60; 95% confidence interval, 0.40-0.92; P=0.02) was associated with an increased risk of bleeding. CONCLUSIONS Reduced pulsatility in patients supported with the continuous-flow LVAD HeartMate II is associated with an increased risk of nonsurgical bleeding, as evaluated by PI.
منابع مشابه
Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device.
BACKGROUND The effects of continuous blood flow and reduced pulsatility on major organ function have not been studied in detail. METHODS AND RESULTS We evaluated renal (creatinine and blood urea nitrogen) and hepatic (aspartate transaminase, alanine transaminase, and total bilirubin) function in 309 (235 male, 74 female) advanced heart failure patients who had been supported with the HeartMat...
متن کاملPulsatility and the Risk of Non-Surgical Bleeding in Patients Supported With the Continuous-Flow Left Ventricular Assist Device HeartMate II Wever-Pinzon et al: LVADs and Non-Surgical Bleeding
rans ns s s s s spl pl pl pl pl pl plan an an an an an ant t t t t t t Pr Pr Pr Pr Pr Pr Prog og og og og og ogra ra ra ra ra ra ra d , y , Sal l lt t t La a a ake k C C C C Cit ity, y, y y UT d dical Ce e e e ent nt nt nt nter er er er e , , Abstract Background—Bleeding is an important cause of morbidity and mortality in patients with
متن کاملEditorial comment: Adverse events in long-term ventricular assist device therapy.
the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...
متن کاملAdvances in Heart Failure Mechanisms of Bleeding and Approach to Patients With Axial-Flow Left Ventricular Assist Devices
During the past several decades, left ventricular assist devices (LVADs) have become a valuable therapeutic option in the management of advanced systolic heart failure. Durable LVADs are being used to provide long-term mechanical circulatory support to a growing population of patients with end-stage systolic heart failure refractory to medical and electric therapies. This advanced stage of hear...
متن کاملAcquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device.
OBJECTIVES The aim of this study was to determine whether differences in continuous flow left ventricular assist devices (LVADs) may lead to differences in the von Willebrand profile and the occurrence of bleeding and thromboembolic events. BACKGROUND The HeartMate II (Thoratec Corp., Pleasanton, California) and HeartWare Ventricular Assist Device (HVAD) (HeartWare, Inc., Framingham, Massachu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Heart failure
دوره 6 3 شماره
صفحات -
تاریخ انتشار 2013