Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter
نویسندگان
چکیده
Purpose: To compare thickness of central cornea measured using Pentacam, Orbscan II, and ultrasound pachymeter Methods: Patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. Central corneal thickness (CCT) was measured by three methods using Pentacam, Orbscan II, and ultrasound pachymeter. Results: Comparison of ultrasound and Orbscan CCT measurements showed a relatively high correlation between these two devices (P<0.001; r=0.891). The 95% limits of agreement (LoA) between these two devices were -42.44 to 20.18 μm. There was also a high correlation between the results obtained through ultrasound and Pentacam (P<0.001; r=0.932). The 95% LoA of CCT with ultrasound and Pentacam were -13.35 to 24.16 μm. There was also a high correlation between CCT measurements carried out by Orbscan and Pentacam (P<0.001) and the 95% LoA were -12.14 to 45.19 μm. Conclusion: The findings of the present study demonstrated high agreements between the CCT readings measured with Orbscan, Pentacam, and ultrasound. The agreement between the Pentacam and ultrasound measurements was higher than that of between Orbscan and ultrasound, making Pentacam a better substitute for ultrasound. Keywords, Central Corneal Thickness, Orbscan, Pentacam, Ultrasound, Agreement Iranian Journal of Ophthalmology 2009;21(2):51-57 © 2009 by the Iranian Society of Ophthalmology 1. Department of Optometry, Mashhad University of Medical Sciences 2. Associate Professor of Ophthalmology, Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences 3. Noor Ophthalmology Research Center, Noor Eye Hospital 4. Department of Optometry, Iran University of Medical Sciences 5. Associate Professor of Epidemiology, Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of
منابع مشابه
Central Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy
PURPOSE To determine inter-device agreement for central corneal thickness (CCT) measurement among ultrasound pachymetry, rotating Scheimpflug imaging (Pentacam, Oculus, Wetzlar, Germany), and scanning slit corneal topography (Orbscan II, Bausch & Lomb, Rochester, NY, USA) in highly myopic eyes before and after photorefractive keratectomy (PRK). METHODS This prospective comparative study inclu...
متن کاملComparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...
متن کاملComparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy
PURPOSE The aim of this study was to determine the agreement between Pentacam HR (Scheimpflug imaging, Oculus) and Orbscan II (scanning slit topography, Bausch and Lomb) in measuring corneal parameters after photorefractive keratectomy (PRK) for hyperopia. METHODS In this prospective cross-sectional study, 38 hyperopic eyes undergoing PRK were examined before refractive surgery and 8 to 10 mo...
متن کاملTopographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor.
PURPOSE To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. METHODS The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obt...
متن کاملCentral corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry.
PURPOSE To assess the intraoperator repeatability and interoperator reproducibility of central corneal thickness measurements by the Pentacam Scheimpflug imaging system (Oculus) and the optical low-coherence reflectometer (OLCR) pachymeter (Haag-Streit) and to compare them with those of ultrasound (US) pachymetry. SETTING Assaf Harofe Medical Center Ophthalmology Outpatient Clinic, Zerifin, I...
متن کامل