Reduction of multiple hits in atom probe tomography.
نویسندگان
چکیده
The accuracy of compositional measurements using atom probe tomography is often reduced because some ions are not recorded when several ions hit the detector in close proximity to each other and within a very short time span. In some cases, for example in analysis of carbides, the multiple hits result in a preferential loss of certain elements, namely those elements that frequently field evaporate in bursts or as dissociating molecules. In this paper a method of reducing the effect of multiple hits is explored. A fine metal grid was mounted a few millimeters behind the local electrode, effectively functioning as a filter. This resulted in a decrease in the overall detection efficiency, from 37% to about 5%, but also in a decrease in the fraction of multiple hits. In an analysis of tungsten carbide the fraction of ions originating from multiple hits decreased from 46% to 10%. As a result, the measured carbon concentration increased from 48.2 at%to 49.8 at%, very close to the expected 50.0 at%. The characteristics of the multiple hits were compared for analyses with and without the grid filter.
منابع مشابه
Localizing of a Four-Level Atom via Absorption Spectrum
We propose a scheme for localizing an atom in a four-level configuration inside a classical standing wave field, conditioned upon the measurement of frequency of a weak probe field. In the classical standing wave field, the interaction between the atom and the field is position dependent due to the Rabi-frequency of the driving field. Hence, as the absorption frequency of the probe field is mea...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملA Non-Demolition Photon Counting Method by Four-Level Inverted Y-Type Atom
The semi-classical model of atom-field interaction has been fully studied for some multilevel atoms, e.g. Vee, L, Cascade X , Y, and inverted Y and so on. This issue is developed into the full-quantum electrodynamics formalism, where the probe and coupling electromagnetic fields are quantized. In this article, we investigate the full-quantum model of absorption and dispersion spectrum of trappe...
متن کاملAtom Probe Tomography Investigations of Modi ed Early Stage Clustering in Si-Containing Aluminum Alloys
In this paper atom probe tomography is used to explore early stage clustering in aluminum alloys. Two novel concepts for a modi cation of clustering are discussed. Control of early stage clustering is welcome from an application point of view since clustering deteriorates strength evolution during the industrial heat treatment of the important class of Al Mg Si precipitation-hardenable alloys. ...
متن کاملAdvanced Nanostructural Analysis of Aluminium Alloys Using Atom Probe Tomography
This paper sets out the needs for and recent advances in microscopy in Al alloys, using solutesolute and solute-vacancy clustering as examples. Cluster-assisted nucleation and cluster strengthening are discussed and this is followed by a discussion of the local electrode atom probe. Heuristic and algorithmic tools for assessing the nanoscale microstructure or nanostructure of Al alloys acquired...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultramicroscopy
دوره 132 شماره
صفحات -
تاریخ انتشار 2013