Effect of complement inhibition and heparin coating on artificial surface-induced leukocyte and platelet activation.
نویسندگان
چکیده
BACKGROUND Exposure of blood to artificial surfaces, as in cardiopulmonary bypass, induces an inflammatory response involving complement, leukocyte and platelet activation. To elucidate the specific role of complement in this process, studies were performed on blood circulated in polyvinyl chloride tubing in the absence and presence of complement inhibitors. Parallel experiments were performed with heparin-coated polyvinyl chloride tubing, which is known to prevent complement and cell activation. METHODS A novel experimental model was used, based on human whole blood anticoagulated with lepirudin. Complement activation products, myeloperoxidase, lactoferrin, and thrombospondin were quantified in enzyme immunoassays. Leukocyte CD11b expression and leukocyte-platelet conjugates were detected by flow cytometry. RESULTS Increased levels of C3 activation products, alternative pathway convertase, and the terminal SC5b-9 complex, combined with unchanged levels of C1rs-C1-inhibitor complexes and marginal changes in C4 activation demonstrated that complement was activated through the alternative pathway. Granulocyte and monocyte CD11b expression and granulocyte-platelet conjugate formation were efficiently attenuated by blocking either factor D, C3, C5, or C5a receptor. In contrast, monocyte-platelet conjugate formation and release of myeloperoxidase, lactoferrin, and thrombospondin were not reduced by complement inhibition. Heparin-coated polyvinyl chloride tubing efficiently reduced all inflammatory markers studied, except for C1rs-C1-inhibitor complexes, which increased, consistent with the enhancing effect of heparin on C1-inhibitor function. This effect did not, however, reduce fluid-phase classic pathway activation induced by heat-aggregated immunoglobulin G. CONCLUSIONS Leukocyte and platelet activation in response to artificial materials occur by mechanisms that vary in their dependence on complement. Heparin coating precludes both the complement-dependent and complement-independent reactions.
منابع مشابه
A heparin-coated circuit reduces complement activation and the release of leukocyte inflammatory mediators during extracorporeal circulation in a rabbit.
Heparin coating modifies complement activation during extracorporeal circulation much more effectively than systemically administered heparin. This rabbit study was undertaken to address possible mechanisms responsible for this difference. We evaluated the effect of heparin coating on complement activation and subsequently the release of leukocyte inflammatory mediators during extracorporeal ci...
متن کاملPii: S1010-7940(99)00143-8
Objective: Complications associated with cardiopulmonary bypass (CPB) have gained more attention due to increased interest in coronary artery bypass grafting without CPB. The impact of heparin coating of CPB circuits has been discussed controversially. The present study examines if the treatment of the oxygenator surface with a synthetic protein may serve as an alternative to a completely hepar...
متن کاملتاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکتها در فراوردههای پلاکتی
Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...
متن کاملLow anticoagulant heparin targets multiple sites of inflammation, suppresses heparin-induced thrombocytopenia, and inhibits interaction of RAGE with its ligands.
While heparin has been used almost exclusively as a blood anticoagulant, important literature demonstrates that it also has broad anti-inflammatory activity. Herein, using low anti-coagulant 2-O,3-O-desulfated heparin (ODSH), we demonstrate that most of the anti-inflammatory pharmacology of heparin is unrelated to anticoagulant activity. ODSH has low affinity for anti-thrombin III, low anti-Xa,...
متن کاملComplement activation on platelet-leukocyte complexes and microparticles in enterohemorrhagic Escherichia coli-induced hemolytic uremic syndrome.
Hemolytic uremic syndrome (HUS) is commonly associated with Shiga toxin (Stx)-producing Escherichia coli O157:H7 infection. This study examined patient samples for complement activation on leukocyte-platelet complexes and microparticles, as well as donor samples for Stx and lipopolysaccharide (O157LPS)-induced complement activation on platelet-leukocyte complexes and microparticles. Results, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Annals of thoracic surgery
دوره 77 3 شماره
صفحات -
تاریخ انتشار 2004