Shielding evaluation of a typical radiography department: a comparison between NCRP reports No.49 and 147
نویسندگان
چکیده
*Corresponding author: Dr. Asghar Mesbahi, Department of Medical Physics, Medical School, Tabriz university of Medical Sciences, Tabriz, Iran. Fax: +98 411 3364660 E-mail: [email protected] Background: Designing and shielding of an appropriate radiography room has been one of the major concerns of radiation scientists since the first decade after the invention of X-rays. Recently, report No.147 of National Council on Radiation Protection and Measurements (NCRP) has been published. In this study the researchers have investigated the effect of new report recommendation on primary and secondary barriers thicknesses in comparison to NCRP 49, and 116 recommendations. Materials and Methods: To calculate the walls thickness of a conventional radiography room, the workload of a radiography room of a university hospital was determined by recording the number of exposures, mAs and kVp for each patient during six months. Three types of calculations were done: (1) Using NCRP 49 formulations and dose limits (2) Using the NCRP 49 formulations and NCRP116 dose limits and (3) Using the NCRP 147 recommendations. Results: The estimated workload was 172 mA min wk-1 for the studied radiography room which was slightly lower than the workload recommended by NCRP147. The results showed that using the NCRP49 formulation and NCRP116 dose limits, the barriers thickness increases substantially. Moreover, the dose limits were lower in NCRP 147, using the third method. The primary barrier thickness is decreased considerably in comparison to two other methods. For the secondary barrier the results of the two methods (1) and (3) did not differ and remained the same. Conclusion: Application of NCRP 49 and NCRP116 dose limits for radiography room shielding (second method) overestimated the primary and secondary barriers thickness, significantly. But, applying NCRP 147, not only the new dose limits were considered, but also the cost of primary barrier construction was reduced. Iran. J. Radiat. Res., 2009; 6 (4): 183188
منابع مشابه
Shielding evaluation of a typical radiography department: a comparison between NCRP reports No.49 and 147
Background: Designing and shielding of an appropriate radiography room has been one of the major concerns of radiation scientists since the first decade after the invention of X-rays. Recently, report No.147 of National Council on Radiation Protection and Measurements (NCRP) has been published. In this study the researchers have investigated the effect of new report recommendation on primary an...
متن کاملComparison of the CT scatter fractions provided in NCRP Report No. 147 to scanner-specific scatter fractions and the consequences for calculated barrier thickness.
The new NCRP Report No. 147 includes methodology to determine x-ray protective shielding for CT scanner rooms. This methodology assumes fixed values of the scatter fraction per centimeter (kappa) for the peripheral axis of the head and body CT phantoms. An investigation was performed to determine kappa for different makes and models of CT scanner and examine the consequences of the differences ...
متن کاملLinear Accelerator Shielding : Thirty Years Beyond NCRP 49
The purpose of this review is to discuss particular shielding problems related to highenergy machines that are not covered in NCRP report No. 49. These include calculating the dose at the end of a maze due to neutrons and capture rays, consideration of high-energy direct-shielded doors, and laminated primary shielding. The impact of special procedures such as IMRT, TBI, and SRS will also be dis...
متن کاملA revised schema for performing diagnostic x-ray shielding calculations.
This paper presents a method for performing diagnostic x-ray shielding calculations which is somewhat different than that given in NCRP Report No. 49. The method computes exposure at the location to be shielded from multiple sources of radiation in the room and accounts for differences in transmission characteristics of leakage and primary/scatter radiation. Also discussed in the paper is a met...
متن کاملSpace Environment and Evaluation of Typical High Altitude Satellite
The space environment consists mainly of high-energy charged particles, such as protons, electrons and heavy ions. They are originating from several sources including galactic cosmic radiation, solar flares and van Allen belts. High energy electromagnetic radiation and neutrons have also been measured on spacecraft. Although shielding can reduce the effect of space radiation it cannot be elimin...
متن کامل