Composition of the Chandra ACIS contaminant
نویسندگان
چکیده
The Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory is suffering a gradual loss of low energy sensitivity due to a buildup of a contaminant. High resolution spectra of bright astrophysical sources using the Chandra Low Energy Transmission Grating Spectrometer (LETGS) have been analyzed in order to determine the nature of the contaminant by measuring the absorption edges. The dominant element in the contaminant is carbon. Edges due to oxygen and fluorine are also detectable. Excluding H, we find that C, O, and F comprise >80%, 7%, and 7% of the contaminant by number, respectively. Nitrogen is less than 3% of the contaminant. We will assess various candidates for the contaminating material and investigate the growth of the layer with time. For example, the detailed structure of the C-K absorption edge provides information about the bonding structure of the compound, eliminating aromatic hydrocarbons as the contaminating material.
منابع مشابه
Update to the ACIS Contamination Model
ACIS observations of astronomical sources as well as its own external calibration source (ECS) have shown that molecular contamination has been building up on the optical/UV blocking filters since launch. Early LETG/ACIS observations of Ton S180 in Nov. 1999 and 3C 273 in Jan. 2000 showed that there was a slight reduction in the low energy ACIS QE1. A nearsimultaneous LETG/HRC-S observation of ...
متن کاملThe Chandra High Resolution Spectra of Mkn 421
Mkn 421 was observed by Chandra twice, on November 5, 1999 as part of the Chandra calibration program, with the ACIS-HETG configuration, and on May 29, 2000 following our Target Of Opportunity request aimed to catch the source in an ultra-high state, with both the ACIS-HETG and the HRC-LETG configurations. In this contribution we present and compare the two Chandra-MEG observations of Mkn 421, ...
متن کاملRefining Chandra/acis Subpixel Event Repositioning Using a Backside-illuminated Ccd Model
Subpixel event repositioning (SER) techniques have been demonstrated to significantly improve the already unprecedented spatial resolution of Chandra X-ray imaging with the Advanced CCD Imaging Spectrometer (ACIS). Chandra CCD SER techniques are based on the premise that the impact position of events can be refined, based on the distribution of charge among affected CCD pixels. ACIS SER models ...
متن کاملN ov 2 00 3 Chandra ACIS and Newton EPIC Observations of the X - ray Luminous SN 1978 K in NGC 1313
We describe an observation of the X-ray luminous SN1978K in NGC 1313 using the ACIS detector on Chandra and an archival Newton EPIC observation. The models that provided good fits to the ASCA SIS and GIS and the ROSAT PSPC spectra no longer do so for the ACIS and EPIC spectra. The best-fit model to the ACIS and EPIC spectra are dual hot plasma models (vmekal); one component is soft (T = 0.61 −0...
متن کاملA Silver Anniversary Observation of the X - Ray Luminous SN 1978 K in NGC 1313
We describe the results of a 2003 Chandra ACIS-I observation of SN 1978K. The spectrum shows little flux below 0.6 keV, in contrast to the 2002 Chandra ACIS-S observation which showed flux to 0.4 keV. Fitting the ACIS-I spectrum alone leads to two solutions depending upon the value of the column density. A joint fit using a dual thermal plasma model applied to the ACIS-I and a contemporaneous X...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003