Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison

نویسنده

  • Laura Mauri
چکیده

Background—Published rates of coronary restenosis have fallen below 10% in drug-eluting stent trials. Early evaluations of new stents have used continuous end points that are presumed surrogates for restenosis, but the generalizability and power of such end points have not been examined systematically. Methods and Results—We examined the relationship between incremental changes in observed late loss in lumen diameter and the probability of restenosis using reported late loss from 22 published trials of various types of stents (bare-metal, drug-eluting, and small-vessel stents). Next, the power of late loss differences was compared with that of corresponding binary restenosis rates. The relationship between mean late loss and its SD was linear and did not vary with stent type (drug-eluting or bare-metal) or vessel diameter. At all levels of late loss examined (0 to 1 mm), incremental changes were associated with increasing restenosis risk (with an increasing magnitude of effect at higher levels of late loss). The power to detect a treatment effect was greater for late loss than for binary angiographic restenosis ( 32% relative increase in power, 24% absolute increase for late loss between 0.2 and 0.6 mm). Conclusions—Late loss is monotonically related to restenosis risk in published stent trials. It is a generalizable and powerful angiographic end point in early or small trials of new drug-eluting stents. (Circulation. 2005;111:3435-3442.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter regarding article by Mauri et al, "Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison".

BACKGROUND Published rates of coronary restenosis have fallen below 10% in drug-eluting stent trials. Early evaluations of new stents have used continuous end points that are presumed surrogates for restenosis, but the generalizability and power of such end points have not been examined systematically. METHODS AND RESULTS We examined the relationship between incremental changes in observed la...

متن کامل

Relationship of late loss in lumen diameter to coronary restenosis in sirolimus-eluting stents.

BACKGROUND Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. METHODS AND RESULTS Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials.

BACKGROUND Binary angiographic and clinical restenosis rates can vary widely between clinical studies, even for the same stent, influenced heavily by case-mix covariates that differ among observational and randomized trials intended to assess a given stent system. We hypothesized that mean in-stent late loss might be a more stable estimator of restenosis propensity across such studies. METHOD...

متن کامل

Letter by Alfonso et al regarding article, "Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis".

BACKGROUND Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. METHODS AND RESULTS One hun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005