Epicardial Catheter Ablation Using High-Intensity Ultrasound: Validation in a Swine Model.

نویسندگان

  • Babak Nazer
  • Vasant Salgaonkar
  • Chris J Diederich
  • Peter D Jones
  • Srikant Duggirala
  • Yasuaki Tanaka
  • Bennett Ng
  • Richard Sievers
  • Edward P Gerstenfeld
چکیده

BACKGROUND Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, while sparing superficial structures. We developed and tested an epicardial HIU ablation catheter in a closed chest, in vivo swine model. METHODS AND RESULTS The HIU catheter is an internally cooled, 14-French, side-facing catheter, integrated with A-mode ultrasound guidance. Swine underwent percutaneous subxyphoid epicardial access and ablation with HIU (n=10 swine) at 15, 20, and 30 W. Compared with irrigated radiofrequency lesions in control swine (n = 5), HIU demonstrated increased lesion depth (HIU 11.6±3.2 mm versus radiofrequency 4.7±1.6 mm; mean±SD) and epicardial sparing (HIU 2.9±2.1 mm versus radiofrequency 0.1±0.2 mm) at all HIU powers, and increased lesion volume at HIU 20 and 30 W (P<0.0001 for all comparisons). HIU ablation over coronary arteries and surrounding epicardial fat resulted in deep lesions with normal angiographic flow. Histological disruption of coronary adventitia, but not media or intima, was noted in 44% of lesions. CONCLUSIONS Compared with radiofrequency, HIU ablation in vivo demonstrates significantly deeper and larger lesions with greater epicardial sparing in a dose-dependent manner. Further development of this catheter may lead to a promising alternative to epicardial radiofrequency ablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Ablation of the sacroiliac joint using MR-guided high intensity focused ultrasound: a preliminary experiment in a swine model

BACKGROUND Dysfunction of the Sacroiliac Joint (SIJ) is one of the key sources of low back pain. For prolonged pain relief, some patients undergo fluoroscopic guided radio-frequency (RF) ablation of SIJ, during which a number of RF probes are inserted to create thermal lesions that disrupt the posterior sacral nerve supply. This procedure is minimally invasive, laborious, time-consuming and cos...

متن کامل

Feasibility of Rapid Linear-Endocardial and Epicardial Ventricular Ablation Using an Irrigated Multipolar Radiofrequency Ablation Catheter.

BACKGROUND A common strategy for ablation of scar-based ventricular tachycardia is delivering multiple lesions in a linear pattern. METHODS AND RESULTS We tested the efficacy of a novel linear irrigated multipolar ablation catheter capable of creating linear lesions with a single application. Healthy swine underwent endocardial and epicardial linear ablation using a novel linear irrigated abl...

متن کامل

Direct visualization of epicardial structures and ablation utilizing a visually guided laser balloon catheter: preliminary findings.

BACKGROUND Intrapericardial mapping and ablation can be utilized to target epicardial arrhythmic circuits. Current epicardial ablation strategies are associated with risk of damage to adjacent structures, including the coronary vasculature and phrenic nerves. OBJECTIVES The purpose of this study was to evaluate the feasibility of an investigational, visually guided laser balloon catheter for ...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 2015