Liquid-Filled Balloon Brachytherapy Using Ga Is Effective and Safe Because of the Short 68-Minute Half-Life Results of a Feasibility Study in the Porcine Coronary Overstretch Model
نویسندگان
چکیده
Background—Liquid-filled balloons for coronary brachytherapy provide significant advantages over solid sources in dose homogeneity but carry the risk of life-threatening radiointoxication after balloon rupture and laboratory contamination in case of a spill. We hypothesized that the positron emitter Ga, with a half-life of only 68 minutes, was well suited to overcome these safety obstacles while providing full therapeutic efficacy. Methods and Results—The feasibility, efficacy, and safety of Ga liquid-filled balloon brachytherapy were investigated in the porcine coronary overstretch model. Four groups of 5 balloon-induced coronary lesions were irradiated with 8, 12, 16, and 24 Gy targeted to the adventitia. Ten unirradiated lesions served as controls. Segments treated with 16 or 24 Gy exhibited marked suppression of neointimal proliferation at 28-day follow-up, with quantitative parameters of intraluminal proliferation reduced to ,20%. This beneficial effect was not compromised by untoward edge effects. Uninjured but irradiated vessels did not show histological signs of radiation damage. The Ga whole-body dose due to balloon rupture was estimated to be 5 rem/50 mCi treatment activity and compared favorably with that of Re (78 rem/50 mCi). Conclusions—Ga positron radiation suppresses neointimal proliferation at doses of 16 and 24 Gy. This biological efficacy, coupled with the attractive safety profile, suggests the selection of Ga as an attractive isotope for liquid-filled balloon brachytherapy. (Circulation. 2001;103:1793-1798.)
منابع مشابه
Liquid-filled balloon brachytherapy using (68)Ga is effective and safe because of the short 68-minute half-life: results of a feasibility study in the porcine coronary overstretch model.
BACKGROUND Liquid-filled balloons for coronary brachytherapy provide significant advantages over solid sources in dose homogeneity but carry the risk of life-threatening radiointoxication after balloon rupture and laboratory contamination in case of a spill. We hypothesized that the positron emitter (68)Ga, with a half-life of only 68 minutes, was well suited to overcome these safety obstacles ...
متن کاملRadioactive 133-Xenon gas-filled balloon to prevent restenosis: dosimetry, efficacy, and safety considerations.
BACKGROUND Ionizing radiation administered intraluminally via catheter-based systems using solid beta and gamma sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (133Xe) radioactive gas-filled balloon catheter system. METHODS AND RESULTS Overstretch balloon injury was performed in...
متن کاملRadioactive 133-Xenon Gas-Filled Balloon to Prevent Restenosis
Background—Ionizing radiation administered intraluminally via catheter-based systems using solid and sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (Xe) radioactive gas-filled balloon catheter system. Methods and Results—Overstretch balloon injury was performed in the coronary ar...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملConsideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation
Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...
متن کامل