Simultaneous determination of estrogenic and androgenic hormones in water by isotope dilution gas chromatography-tandem mass spectrometry.

نویسندگان

  • Trang Trinh
  • Nick B Harden
  • Heather M Coleman
  • Stuart J Khan
چکیده

A rapid gas chromatography-tandem mass spectrometry (GC-MS/MS) analytical method was developed for the simultaneous analysis of 7 estrogenic hormones (17α-estradiol, 17β-estradiol, estrone, mestranol, 17α-ethynylestradiol, levonorgestrel, estriol) and 5 androgenic hormones (testosterone, androsterone, etiocholanolone, dihydrotestosterone, androstenedione) in aqueous matrices. This method is unique in its inclusion of all 12 of these estrogens and androgens and is of particular value due to its very short chromatographic run time of 15 min. The use of isotope dilution for all analytes ensures the accurate quantification, accounting for analytical variabilities that may be introduced during sample processing and instrumental analysis. Direct isotopically labelled analogues were used for 8 of the 12 hormones and satisfactory isotope standards were identified for the remaining 4 hormones. Method detection levels (MDLs) were determined to describe analyte concentrations sufficient to provide a signal with 99% certainty of detection. The established MDLs for most analytes were 1-5 ngL(-1) in a variety of aqueous matrices. However, slightly higher MDLs were observed for etiocholanolone, androstenedione, testosterone, levonorgestrel and dihydrotestosterone in some aqueous matrices. Sample matrices were observed to have only a minor impact on MDLs and the method validation confirmed satisfactory method stability over intra-day and inter-day analyses of surface water and tertiary treated effluent samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of estrogenic hormones in municipal wastewater effluent and surface water using enzyme-linked immunosorbent assay and gas chromatography/tandem mass spectrometry.

Although the estrogenic hormones 17 beta-estradiol and 17 alpha-ethinyl estradiol can be quantified in polluted waters by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/tandem mass spectrometry (GC/MS/MS), the compounds often are present at concentrations below detection limits. Enzyme-linked immunosorbent assays (ELISAs) provide a sensitive and robust means of quantifying ...

متن کامل

Analysis of N-nitrosamines in water by isotope dilution gas chromatography-electron ionisation tandem mass spectrometry.

A method has been developed for the determination of eight N-nitrosamines in drinking water and treated municipal effluent. The method uses solid phase extraction (SPE), gas chromatography (GC) and analysis by tandem mass spectrometry (MS-MS) with electron ionization (EI). The target compounds are N-nitrosodimethylamine (NDMA), N-nitrosomethyethylamine (NMEA), N-nitrosodiethylamine NDEA), N-nit...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.

Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1218 12  شماره 

صفحات  -

تاریخ انتشار 2011