Towards in-process x-ray CT for dimensional metrology
نویسندگان
چکیده
X-ray computed tomography (CT) offers significant potential as a metrological tool, given the wealth of internal and external data that can be captured, much of which is inaccessible to conventional optical and tactile coordinate measurement machines (CMM). Typical lab-based CT can take upwards of 30 min to produce a 3D model of an object, making it unsuitable for volume production inspection applications. Recently a new generation of real time tomography (RTT) x-ray CT has been developed for airport baggage inspections, utilising novel electronically switched x-ray sources instead of a rotating gantry. This enables bags to be scanned in a few seconds and 3D volume images produced in almost real time for qualitative assessment to identify potential threats. Such systems are able to scan objects as large as 600 mm in diameter at 500 mm s−1. The current voxel size of such a system is approximately 1 mm—much larger than lab-based CT, but with significantly faster scan times is an attractive prospect to explore. This paper will examine the potential of such systems for real time metrological inspection of additively manufactured parts. The measurement accuracy of the Rapiscan RTT110, an RTT airport baggage scanner, is evaluated by comparison to measurements from a metrologically confirmed CMM and those achieved by conventional lab-CT. It was found to produce an average absolute error of 0.18 mm that may already have some applications in the manufacturing line. While this is expectedly a greater error than labbased CT, a number of adjustments are suggested that could improve resolution, making the technology viable for a broader range of in-line quality inspection applications, including cast and additively manufactured parts.
منابع مشابه
Dimensional X-ray Computed Tomography and its Evaluation Method of Measurement Capability
An X-ray computed tomography (CT) system that is capable of dimensional measurements is incleasingly propergating in our life because the realization of simultaneous nondestructive dimensional measurements for outward forms and inward forms on dense spatial points in short time duration remarkably facilitates production loop. However, the X-ray CT is still not applicable to all of industrial ob...
متن کاملQuality evaluation of X-ray computed tomography volume data in dimensional metrology
This paper presents a method for evaluating the quality of X-ray computed tomography (CT) volume data for dimensional metrology. In the method entropy defined on the distribution of CT values of volume data is used as a criterion. For a local geometric feature of a specimen, concepts defined in GD&T are used as reference to define the evaluation area for entropy calculation. Some scannings with...
متن کاملAn initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology
X-ray computed tomography (CT) enables the visualisation and dimensional evaluation of both the internal and external geometry of a workpiece, it is therefore well suited for measuring geometric features that are otherwise inaccessible to tactile and optical instruments. Beam hardening is a wellknown physical process that can degrade the quality of CT images and influence edge detection algorit...
متن کاملThe Application of Voxel Size Correction in X-ray Computed Tomography for Dimensional Metrology
X-ray computed tomography (CT) is a non-destructive, radiographic scanning technique that enables the visualisation and dimensional evaluation of both internal and external features of a workpiece; it is therefore an attractive alternative for measurement tasks that prove problematic for conventional tactile and optical instruments. The data output of a CT measurement is a volume of grey value ...
متن کاملFully-Automated 3D Metrology and Defect Analysis with High-Resolution 300 kV Microfocus Computed Tomography
With industrial X-ray computed tomography (CT), even low-contrast defects in cast parts, such as cracks, pores and blowholes, can be localized and measured in three dimensions. Analysis of the defects can be performed using either multi-positional 2D cross-section planes or the 3D volume view. Additionally, 3D metrology with CT becomes more and more an effective tool for many tasks in productio...
متن کاملBeam hardening correction and its influence on the measurement accuracy and repeatability for CT dimensional metrology applications
The beam hardening effect is one of the major artifacts of X-ray computed tomography. It not only complicates medical inspection and material analysis, but also influences the accuracy and repeatability of dimensional measurements. Therefore, many efforts have been devoted to develop beam hardening correction methods since the early 1970s. In practice, the combination of hardware filters (pre-f...